8.
Press
Power
on
the
control
panel.
The
system
takes
approximately
10
to
45
minutes
to
power
on
and
progress
through
an
IPL
far
enough
to
continue
with
these
instructions.
You
should
see
that
the
data
changes
in
the
Function/Data
display.
The
last
step
of
the
IPL
may
take
up
to
30
minutes
to
complete
or
the
Attention
light
may
turn
on.
9.
Reference
code
x6004031
or
x6004508
(where
x
can
be
any
letter)
will
appear
in
the
Function/Data
display
and
remain
for
up
to
30
minutes.
10.
When
the
system
has
completed
the
initial
phase
of
the
manual
IPL
it
should
show
01
B
and
you
have
a
console.
Note:
Some
system
reference
codes
(SRCs)
can
be
displayed
without
the
attention
light
being
on.
One
example
is
x6xx450x
(where
the
x
can
be
any
letter
or
number).
These
SRC
codes
typically
indicate
that
the
system
detected
an
unexpected
condition,
and
the
console
might
have
data
indicating
this
condition.
This
condition
and
the
resulting
console
data
precede
the
IPL
or
Install
the
System
window.
If
the
Attention
light
is
lit,
then
go
to
step
11.
If
the
Attention
light
is
not
lit
and
you
do
not
have
a
console,
then,
consider
the
following:
v
Your
system
may
not
have
progressed
through
an
IPL
far
enough
to
continue
with
these
instructions.
Wait
at
least
30
minutes
before
going
any
further.
v
If,
after
30
minutes,
you
do
not
see
any
system
activity
and
the
Attention
light
did
not
light:
See
the
information
about
handling
and
reporting
system
problems
in
the
Troubleshooting
and
service
topic.
v
When
the
problem
has
been
resolved,
start
at
the
beginning
of
this
section
again.
11.
If
you
see
System
Reference
Code
(SRC)
x6xx500x
(where
the
x
can
be
any
letter
or
number)
in
the
Function/Data
display,
then,
go
to
the
Troubleshoot
system
reference
code
(SRC)
data
topic
for
details.
If
you
do
not
see
System
Reference
Code
(SRC)
x6xx500x
(where
the
x
can
be
any
letter
or
number)
in
the
Function/Data
display,
then,
see
the
information
about
handling
and
reporting
system
problems
in
the
Troubleshooting
and
service
topic.
Note:
If
you
are
working
with
a
console
related
problem
the
most
common
SRC
code
reported
would
be
A6005008.
If
you
see
any
reference
code
of
A600500x
(where
x
can
be
any
number)
then
you
can
proceed
with
any
console
service
functions
(65+21)
to
debug
or
make
changes.
Related
reference
If
you
receive
any
of
these
system
reference
codes
(SRCs),
you
might
have
some
problems
in
your
Operations
Console
configuration.
Related
information
Activating
the
asynchronous
communications
line
on
the
system
These
instructions
apply
only
to
local
console
directly
attached
and
local
console
directly
attached
with
remote-support-enabled
configurations.
Use
these
instructions
to
manually
activate
the
asynchronous
communications
line
on
the
system.
1.
If
your
system
uses
a
keystick,
insert
it
in
the
key
slot
now.
2.
Place
the
system
into
manual
mode
by
using
the
system’s
control
panel.
3.
Using
Up
and
Down
,
select
function
25
and
press
Enter.
4.
Use
the
Up
to
select
function
26
and
press
Enter
.
5.
Use
the
Down
to
select
function
66
and
press
Enter
.
The
system
attempts
to
initialize
the
attached
modem.
If
it
is
successful,
the
Function/Data
window
displays
D1008066
.
If
the
system
could
not
initialize
the
modem,
it
displays
D1008065
.
Related
tasks
Operations
Console
91
Summary of Contents for System i
Page 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 2: ......
Page 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 8: ...vi System i Connecting to System i Operations Console ...
Page 120: ...112 System i Connecting to System i Operations Console ...
Page 124: ...116 System i Connecting to System i Operations Console ...
Page 125: ......
Page 126: ... Printed in USA ...