You
need
to
meet
the
PC
and
System
i
hardware
requirements
for
an
Operations
Console
configuration.
Changing
the
console
from
a
local
console
directly
attached
to
a
local
console
on
a
network
(LAN)
in
a
non-partitioned
or
primary
partitioned
system:
To
change
from
an
Operations
Console
with
local
console
directly
attached
to
a
local
console
on
a
network
(LAN),
follow
these
steps
on
the
system,
using
the
existing
console.
1.
Access
Dedicated
Service
Tools
(DST)
or
System
Service
Tools
(SST).
2.
Select
Work
with
DST
environment
.
You
must
unlock
the
SST
option
Service
tools
device
IDs
before
it
is
usable.
3.
Select
System
Devices
(skip
this
step
if
using
SST).
4.
Select
Select
Console
.
5.
Select
Operations
Console
(LAN)
.
The
Verify
Operations
Console
Adapters
window.
This
is
the
resource
found
by
the
system
to
be
used
for
your
LAN
connection.
If
you
get
a
message
stating
that
the
LAN
adapter
was
not
found,
you
have
not
satisfied
the
hardware
requirements
for
Operations
Console.
6.
Press
F11
to
configure
the
adapter.
7.
Enter
the
appropriate
network
data.
8.
Press
F7
to
store
the
data.
9.
Press
F14
to
activate
the
adapter
for
use
by
Operations
Console.
10.
Press
F3
to
return
to
the
DST
main
menu.
The
system
is
now
configured
for
use
by
Operations
Console
local
console
on
a
network
when
an
action
is
taken
to
search
for
a
new
console.
This
could
include
an
IPL,
the
native
macro,
or
the
console
service
function
(65+21).
Do
NOT
take
an
action
to
switch
to
the
new
console
until
you
have
satisfied
any
necessary
PC
configurations.
The
system
value
QAUTOCFG
must
be
set
to
on.
Use
one
of
the
following
methods
to
verify
or
set
this
system
value:
v
Use
the
WRKSYSVAL
QAUTOCFG
command.
v
During
a
manual
IPL,
in
the
IPL
Options
window,
select
Y
for
Set
major
system
options
.
Then,
for
Enable
automatic
configuration
,
select
Y
.
Continue
with
Configure
the
PC
to
use
the
new
console
type.
Related
tasks
To
change
from
an
Operations
Console
with
local
console
directly
attached
to
a
local
console
on
a
network
(LAN),
you
must
configure
the
PC
to
use
the
new
console
type.
Related
reference
You
need
to
meet
the
PC
and
System
i
hardware
requirements
for
an
Operations
Console
configuration.
Related
information
Changing
the
console
from
a
local
console
directly
attached
to
a
local
console
on
a
network
in
a
logical
partition:
Operations
Console
67
|
Summary of Contents for System i
Page 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 2: ......
Page 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 8: ...vi System i Connecting to System i Operations Console ...
Page 120: ...112 System i Connecting to System i Operations Console ...
Page 124: ...116 System i Connecting to System i Operations Console ...
Page 125: ......
Page 126: ... Printed in USA ...