To
change
from
an
Operations
Console
with
a
local
console
directly
attached
to
a
local
console
on
a
network
(LAN),
follow
these
steps
on
the
system
using
the
existing
console.
Note:
If
you
need
to
add
or
move
adapters
to
satisfy
the
hardware
requirements
for
Operations
Console,
do
this
work
prior
to
starting
these
steps.
1.
Access
Dedicated
Service
Tools
(DST)
or
System
Service
Tools
(SST).
You
must
unlock
the
SST
option
″
Service
tools
device
IDs
″
before
it
is
usable.
2.
Select
Work
with
System
Partitions
.
3.
Select
Work
with
partition
configuration
.
4.
Choose
Select
Console
Resource
on
the
logical
partition.
5.
Press
F9
to
Change
capability
filter
.
6.
Select
Any
Console
.
7.
To
select
the
IOP
that
will
support
your
intended
console,
do
one
of
the
following:
v
If
the
adapter
to
be
used
for
the
intended
console
is
under
the
same
IOP
as
the
previous
console’s
adapter,
the
console
IOP
is
already
correctly
tagged.
Go
to
step
8.
v
If
the
adapter
to
be
used
for
the
intended
console
is
under
a
different
IOP
than
the
currently
configured
console,
place
a
1
in
front
of
the
IOP
to
select
it
as
the
console
IOP.
8.
Verify
an
adapter
for
Electronic
Customer
Support
(ECS)
and
an
optional
alternate
console
(twinaxial
console
only).
Note:
The
selection
of
an
alternate
console
only
pertains
when
twinaxial
workstations
are
to
be
the
alternate
console
and
the
console
type
is
also
twinaxial
console.
The
alternate
console
must
be
under
a
different
IOP
than
the
IOP
tagged
for
use
by
Operations
Console.
Operations
Console
cannot
be
used
as
an
alternate
console.
v
To
verify
the
console
IOP
for
ECS,
perform
the
following
steps:
Note:
If
you
use
Operations
Console
as
your
console
type,
you
must
also
tag
the
same
IOP
used
for
the
console
as
the
IOP
for
ECS.
a.
Press
F12
until
you
arrive
at
the
Work
with
Partition
Configuration
window.
b.
Enter
a
9
in
front
of
the
partition
to
be
tagged
for
ECS.
c.
Look
at
the
symbols
on
the
same
line
as
the
tagged
console
IOP
(the
console
tag
is
the
<
symbol)
for
the
ECS
symbol,
which
is
the
+
(the
plus
sign).
If
the
+
symbol
is
shown,
the
IOP
is
correctly
tagged
for
ECS.
Go
to
step
9.
d.
To
tag
the
console
IOP
for
ECS,
enter
a
1
in
front
of
the
IOP
to
be
tagged
for
ECS.
Note:
If
you
will
be
using
Operation
Console
as
the
intended
console
you
should
now
see
both
a
<
and
a
+
associated
with
the
console
IOP.
9.
Press
F3
to
exit
to
the
DST
main
menu.
10.
Select
Work
with
DST
environment
.
11.
Select
System
Devices
(skip
this
step
if
using
SST).
12.
Select
Select
Console
.
13.
Select
Operations
Console
(LAN)
:
a.
The
Verify
Operations
Console
Adapters
window
appears.
This
is
the
resource
found
by
the
system
to
be
used
for
your
LAN
connections.
If
you
receive
the
message
No
valid
LAN
adapter
available
you
did
not
satisfy
the
hardware
requirements
for
Operations
Console.
If
so,
use
F3
to
exit
to
the
DST
main
menu,
then,
start
this
topic
again
at
step
1.
b.
Press
F11
to
configure
the
adapter.
c.
Enter
the
appropriate
network
data.
d.
Press
F7
to
store
the
data.
e.
Press
F14
to
activate
the
adapter
for
use
by
Operations
Console.
68
System
i:
Connecting
to
System
i
Operations
Console
|
|
|
|
|
|
Summary of Contents for System i
Page 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 2: ......
Page 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 8: ...vi System i Connecting to System i Operations Console ...
Page 120: ...112 System i Connecting to System i Operations Console ...
Page 124: ...116 System i Connecting to System i Operations Console ...
Page 125: ......
Page 126: ... Printed in USA ...