xxxxxxxx
Each
word
is
8
characters
only
and
displayed
individually.
If
you
want
word
17,
you
have
to
request
function
17.
The
data
provided
in
the
words
can
be
accessed
using
many
different
methods.
Important:
In
order
to
know
where
you
are
in
the
process
the
following
information
is
provided:
v
Word
17
of
the
SRC
D1008065
will
contain
the
the
number
of
function
65s
you
have
done.
When
it
reaches
a
count
of
7,
the
reset
of
the
service
tools
device
ID
password
will
take
place.
Word
18
will
then
be
set
to
00000000
.
v
Word
18
will
show
00000001
until
you
have
entered
the
seventh
function
65.
When
the
reset
has
completed,
this
word
will
be
set
to
00000000
unless
more
than
five
minutes
have
elapsed.
Note:
If
you
enter
function
65
more
than
seven
times,
the
count
will
start
over.
3.
Use
one
of
the
following
methods
to
reset
the
QCONSOLE
service
tools
device
ID
depending
on
the
partition
type:
v
For
independent
systems
or
primary
partitions,
follow
these
steps:
a.
From
the
control
panel,
use
the
Up
or
Down
buttons
so
that
Function/Data
display
shows
25
.
Then
press
the
Enter
button.
The
Function/Data
display
should
show
25
00
.
b.
Use
the
Up
button
once
to
increment
the
data
to
26
.
Then,
press
the
Enter
button.
The
system
will
most
likely
respond
with
01
B
in
the
Function/Data
display.
Note:
If
the
system
responds
with
65
FF
repeat
steps
a
and
b
again.
c.
Using
the
Down
button,
decrement
the
data
to
65
,
and
then
press
the
Enter
button.
The
system
will
respond
with
65
00
.
After
processing
the
function
the
system
will
respond
with
a
D1008065.
Repeat
this
step
so
that
you
have
entered
7
function
65s.
You
will
have
five
minutes
to
complete
this
task.
When
the
seventh
65
is
entered
and
if
it
is
found
that
greater
than
five
minutes
have
elapsed,
the
reset
will
not
be
processed
and
the
count
will
return
to
zero.
Check
WORD17
to
verify
that
the
system
handled
each
request.
Entering
the
65s
quickly
may
cause
the
system
to
miss
the
entries.
v
For
secondary
partitions,
follow
these
steps
using
the
console
on
the
primary
partition:
a.
Access
Dedicated
Service
Tools
(DST)
or
System
Service
Tools
(SST).
Note:
You
must
unlock
the
SST
option
before
the
option
is
usable.
b.
Select
Work
with
system
partitions
.
c.
Select
Work
with
partition
status
.
Note:
If
the
partition
on
which
the
reset
will
be
performed
is
not
in
manual
mode,
you
need
to
force
the
partition
into
manual
mode
by
placing
a
10
on
the
line
for
the
partition
selection
area
before
continuing.
d.
Enter
a
65
on
the
line
for
the
partition
to
be
reset,
then
press
Enter.
e.
Repeat
this
step
so
that
you
have
entered
7
function
65s.
You
will
have
five
minutes
to
complete
this
task.
When
the
seventh
65
is
entered
and
more
than
five
minutes
have
elapsed,
the
reset
will
not
be
processed
and
the
count
will
return
to
zero.
Proceed
to
reset
the
service
tools
device
ID
password
on
the
PC.
Resetting
the
service
tools
device
ID
password
on
the
PC:
You
no
longer
need
to
manually
reset
a
connections
service
tools
device
ID
password
on
the
client
PC.
Operations
Console
83
Summary of Contents for System i
Page 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 2: ......
Page 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 8: ...vi System i Connecting to System i Operations Console ...
Page 120: ...112 System i Connecting to System i Operations Console ...
Page 124: ...116 System i Connecting to System i Operations Console ...
Page 125: ......
Page 126: ... Printed in USA ...