14.
Press
F3
until
you
return
to
the
DST
main
menu.
The
system
is
now
configured
for
use
by
Operations
Console
local
console
on
a
network
when
an
action
is
taken
to
search
for
a
new
console.
This
could
include
an
IPL,
the
native
macro,
or
the
console
service
function
(65+21).
Do
NOT
take
an
action
to
switch
to
the
new
console
until
you
have
satisfied
any
necessary
PC
configurations.
If
you
do
not
plan
to
use
the
local
console
directly
attached
configuration
as
a
backup
console,
you
do
not
need
to
remove
or
move
its
adapter
at
this
time.
You
may
need
it
to
debug
problems.
The
system
value
QAUTOCFG
must
be
set
to
on.
Use
one
of
the
following
methods
to
verify
or
set
this
system
value:
v
Use
the
WRKSYSVAL
QAUTOCFG
command.
v
During
a
manual
IPL,
in
the
IPL
Options
window,
select
Y
for
Set
major
system
options.
Then,
for
Enable
automatic
configuration
,
select
Y
.
Related
tasks
To
change
from
an
Operations
Console
with
local
console
directly
attached
to
a
local
console
on
a
network
(LAN),
you
must
configure
the
PC
to
use
the
new
console
type.
Related
reference
You
need
to
meet
the
PC
and
System
i
hardware
requirements
for
an
Operations
Console
configuration.
Related
information
Configuring
the
PC
to
use
the
new
console
type
when
changing
from
a
local
console
directly
attached
to
a
local
console
on
a
network:
To
change
from
an
Operations
Console
with
local
console
directly
attached
to
a
local
console
on
a
network
(LAN),
you
must
configure
the
PC
to
use
the
new
console
type.
Follow
these
steps
on
the
PC:
1.
Disconnect
the
current
console
connection.
To
disconnect,
do
the
following:
a.
Select
the
configuration
name
(under
iSeries
Connection).
This
is
the
name
that
Operations
Console
uses
to
refer
to
a
specific
system.
b.
From
the
Connection
menu,
click
Disconnect
.
The
connection
status
shows
Disconnecting
.
c.
Wait
for
the
status
to
show
Disconnected
.
2.
Configure
the
new
console
type.
It
is
preferred
that
you
perform
an
initial
program
load
(IPL)
to
be
certain
there
are
no
errors.
Once
you
are
satisfied
that
the
new
console
is
working
correctly,
you
can
proceed
with
any
plans
to
move
or
remove
any
adapter
or
configurations.
If
you
do
not
use
the
cabled
connection
as
a
backup
console,
you
can
remove
the
console
cable,
the
remote
control
panel
cable,
or
both
cables
from
the
PC
at
this
time.
To
avoid
potential
errors,
turn
off
the
system
before
removing
or
adding
cables
from
the
system.
To
delete
the
current
configuration
if
you
will
not
be
using
the
cabled
connection
as
a
backup
console,
do
the
following:
a.
Select
the
configuration
name
(under
iSeries
Connection).
b.
From
the
Connection
menu,
click
Delete
.
c.
Click
Yes
to
confirm
the
deletion.
Operations
Console
69
|
|
|
Summary of Contents for System i
Page 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 2: ......
Page 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...