v
During
a
manual
IPL,
in
the
IPL
Options
window,
select
Y
for
Set
major
system
options.
Then,
for
Enable
automatic
configuration
,
select
Y
.
Related
reference
You
need
to
meet
the
PC
and
System
i
hardware
requirements
for
an
Operations
Console
configuration.
To
change
from
a
twinaxial
console
to
an
Operations
Console,
you
must
configure
the
PC
to
use
the
new
console
type.
Related
information
Configuring
the
PC
to
use
the
new
console
type
after
changing
from
a
twinaxial
console
to
an
Operations
Console:
To
change
from
a
twinaxial
console
to
an
Operations
Console,
you
must
configure
the
PC
to
use
the
new
console
type.
It
is
preferred
that
you
perform
an
initial
program
load
(IPL)
to
ensure
there
are
no
errors.
Then,
at
a
later
time,
remove
or
move
any
hardware
you
planned
for.
It
is
perferred
that
you
turn
off
the
iSeries
when
removing
adapter
cards
or
cables.
Note:
If
the
new
console
fails
to
work
in
i5/OS
you
may
need
to
use
another
workstation
to
manually
delete
the
controller
and
device
description
associated
with
the
old
console
device.
Related
concepts
After
you
complete
the
planning
requirements
and
know
which
configuration
and
PC
operating
system
you
will
be
using,
you
can
create
and
go
through
a
checklist
for
setting
up
Operations
Console.
Changing
from
an
Operations
Console
to
a
twinaxial
console
To
change
from
an
Operations
Console
to
a
twinaxial
console,
you
must
perform
steps
on
the
system
and,
optionally,
on
the
PC.
Before
you
begin,
make
sure
that
you
have
satisfied
all
the
Operations
Console
hardware
requirements
for
the
PC
and
the
system.
Related
reference
You
need
to
meet
the
PC
and
System
i
hardware
requirements
for
an
Operations
Console
configuration.
Changing
the
console
from
an
Operations
Console
to
a
twinaxial
console
in
a
non-partitioned
or
primary
partitioned
system:
To
change
from
an
Operations
Console
to
a
twinaxial
console,
follow
these
steps
on
the
system
using
the
existing
console.
1.
Access
Dedicated
Service
Tools
(DST)
or
System
Service
Tools
(SST).
2.
Select
Work
with
DST
environment
.
3.
Select
System
Devices
(skip
this
step
if
using
SST).
4.
Select
Select
Console
.
76
System
i:
Connecting
to
System
i
Operations
Console
|
|
Summary of Contents for System i
Page 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 2: ......
Page 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 8: ...vi System i Connecting to System i Operations Console ...
Page 120: ...112 System i Connecting to System i Operations Console ...
Page 124: ...116 System i Connecting to System i Operations Console ...
Page 125: ......
Page 126: ... Printed in USA ...