A6005007
A
console
device
was
not
found
during
a
manual
IPL.
This
SRC
is
also
indicating
the
presence
of
hardware
that
may
indicate
another
console
type
other
than
twinaxial
or
Operations
Console
(Direct)
was
found.
An
example
would
be
the
old
async
console,
which
is
no
longer
supported.
This
is
not
indicating
a
failure
of
that
hardware
or
that
it
is
the
intended
console.
These
SRCs,
as
well
as
the
attention
light,
are
reset
when
a
console
is
detected
and
becomes
active.
If
one
of
these
SRCs
exists
for
a
long
time,
you
might
need
to
perform
an
IPL
to
try
to
find
a
console
device,
depending
on
many
factors,
including
the
model
and
the
hardware
present.
You
can
force
the
system
to
try
finding
the
console
again
by
using
function
21
from
the
control
panel,
remote
control
panel,
or
virtual
control
panel.
You
can
also
use
the
65+21
functions
to
gather
data
or
attempt
recovery.
System
reference
code
A6005008
Use
this
table
if
you
received
system
reference
code
(SRC)
A6005008.
If
an
IPL
did
not
find
a
console
and
if
the
console
type
is
set
to
anything
except
a
1,
the
system
will
display
code
A6005008.
v
If
you
are
attempting
to
use
a
twinaxial
console
the
only
data
relevant
in
this
SRC
is
word
16.
Use
the
following
table
to
determine
the
twinaxial
failure.
The
first
4
characters
of
this
word
contains
the
last
4
characters
of
the
original
failure
type.
For
example,
if
word
16
contained
50010001,
the
twinaxial-related
SRC
would
be
A6005001
and
the
console
type
is
set
to
use
a
twinaxial
console.
Refer
to
that
SRC.
v
If
you
are
attempting
to
use
Operations
Console
select
the
appropriate
section
in
the
table
below
as
follows:
–
Local
console
on
a
network
uses
words
13,
14,
and
15.
–
Local
console
directly
attached
to
the
server
uses
words
17,
18,
and
19.
Note:
If
you
just
replaced
the
LAN
adapter
associated
with
Operations
Console
(LAN),
you
need
to
wait
at
least
35
minutes
for
the
system
to
find
and
use
the
new
LAN
adapter.
In
this
case,
when
the
system
is
satisfied,
it
starts
using
the
new
adapter.
The
console
should
start,
and
the
SRC
is
no
longer
shown.
LAN
If
Word
13
value
is:
Failure
Word
14
means:
Word
15
means:
1
No
supported
HW
detected
or
HW
detected
is
not
expected
(for
example,
you
replaced
the
LAN
IOA
so
the
serial
number
is
different)
In
some
cases
the
serial
number
of
the
expected
adapter
may
be
shown.
2
LAN
IOA
failed
to
report
3
Hardware
error
Common
error
codes:
53001A80,53002AC0
Network,
cable
or
the
LAN
adapter
may
not
be
operational.
Error
code:
00000000
.
This
error
code
indicates
the
adapter
reported
but
has
not
been
initialized
yet.
This
is
not
considered
an
error,
at
this
time.
The
adapter
should
be
activated
shortly.
For
other
error
codes
contact
your
service
provider.
Card
position
or
serial
number
of
adapter
106
System
i:
Connecting
to
System
i
Operations
Console
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for System i
Page 1: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 2: ......
Page 3: ...System i Connecting to System i Operations Console Version 5 Release 4 ...
Page 8: ...vi System i Connecting to System i Operations Console ...
Page 120: ...112 System i Connecting to System i Operations Console ...
Page 124: ...116 System i Connecting to System i Operations Console ...
Page 125: ......
Page 126: ... Printed in USA ...