Table 6. Service Processor Error Codes. (continued)
Error Code Description
Action/
Possible Failing FRU
406A 0BF0 I/O slot 0, I/O port x (problem outside
the CEC drawer)
Go to “MAP 1540: Minimum
Configuration” on page 101.
406A 0CA5 Invalid processor configuration
Check that the processor cards are
properly installed and configured.
406A 0CA6 No usable memory left in the system.
The system must be rebooted.
Go to “MAP 1240: Memory Problem
Resolution” on page 73.
406A 0CA9 Incorrect/incompatible memory DIMMs
are installed.
Check that the memory DIMMs are
properly configured, and are the right
type for the system.
406A 0CAA System memory exceeds the limit for
this system type and model.
Remove the memory DIMMs until the
memory does not exceed the limit for
this system type and model.
406A 0EA0 MOPS service processor code error.
1. Check for system firmware updates.
2. Call service support.
406A 0EA1 Operating system code on main
processor
1. Check for operating system code
updates.
2. Call service support.
406A 0EA2 PRD code on service processor error.
1. Check for system firmware updates.
2. Call service support.
406A 0EA4 Service processor code problem
Contact next level of support.
406A 0EAF Service processor code and system
type are unknown
1. Check for system firmware updates.
2. Call service support.
406A 0EB0 JTAG problem
Go to “MAP 1541: JTAG Problem
Isolation” on page 122.
406A 0EB1 Attention line 0 stuck fault
Go to “MAP 1540: Minimum
Configuration” on page 101.
406A 0EB2 Attention line 1 stuck fault
Go to “MAP 1540: Minimum
Configuration” on page 101.
406A 0EB3 Attention line 2 stuck fault
Go to “MAP 1540: Minimum
Configuration” on page 101.
406A 0EB4 Attention line 3 stuck fault
Go to “MAP 1540: Minimum
Configuration” on page 101.
406A 0EB5 Attention line 4 stuck fault
Go to “MAP 1540: Minimum
Configuration” on page 101.
406A 0EB6 Attention line 5 stuck fault
Go to “MAP 1540: Minimum
Configuration” on page 101.
406A 0EB7 Attention line 6 stuck fault
Go to “MAP 1540: Minimum
Configuration” on page 101.
406A 0EB8 Attention line 7 stuck fault
Go to “MAP 1540: Minimum
Configuration” on page 101.
206
Eserver
pSeries 630 Models 6C4 and 6E4 Service Guide
Summary of Contents for eserver 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 00 ERserver IBM ...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 00 ERserver IBM ...
Page 16: ...xiv Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 18: ...xvi Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 52: ...System Logic Flow Diagram 32 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 64: ...Internal Signal Cable Routing Diagram 44 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 70: ...50 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 302: ...282 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 350: ...330 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 366: ...346 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 478: ...System Parts 458 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 480: ...System Parts continued 460 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 482: ...Model 6E4 Cover Set and Brackets 462 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 484: ...464 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 494: ...474 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 504: ...484 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 508: ...488 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 526: ...506 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 536: ...516 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 560: ...540 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 568: ...548 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 571: ......
Page 572: ...IBM Printed in U S A August 2002 SA38 0604 00 ...