Table 5. Firmware Error Codes. (continued)
Error Code Description
Action/
Possible Failing FRU
2602 0011 Description: PCI probe error, bridge is not usable
Action: If the location code identifies a slot:
1. Check the cabling to the adapter. In particular, the adapters that have serial
ports. Serial ports may require null modems or special cabling configurations
to avoid connecting driver outputs together. This may create a PCI slot power
problem and force the adapter to be deconfigured.
2. Move adapter to another slot (behind a different PCI bus).
3. Check for available firmware updates for adapter. Apply update if available.
4. Replace adapter.
5. Check for system firmware updates. Apply update if available.
6. Replace PCI riser card,
Location: U0.1-P2
2602 0012 Description: PCI device run-time error, bridge in freeze state
Action: If the location code identifies a slot:
1. Check the cabling to the adapter. In particular, the adapters that have serial
ports. Serial ports may require null modems or special cabling configurations
to avoid connecting driver outputs together. This may create a PCI slot power
problem and force the adapter to be deconfigured.
2. Move adapter to another slot (behind a different PCI bus).
3. Check for available firmware updates for adapter. Apply update if available.
4. Replace adapter.
5. Check for system firmware updates. Apply if update available.
6. Replace PCI riser card
Location: U0.1-P2
2680 0Axy MX-PCI bridge BIST failure
Replace the PCI riser card,
Location: U0.1-P2
See “Determining Location Code” on
page 154 or location code information
related to this error.
2680 0Cxx Machine check occurred
1. Replace the part identified by the
location code associated with this
error code.
2. If the location code associated with
this error code identifies an adapter,
and replacing the adapter does not
correct the problem, replace the PCI
riser card
Location: U0.1-P2
2680 0Dxx Machine check occurred; unable to
isolate to a single device
Go to “MAP 1540: Minimum
Configuration” on page 101
178
Eserver
pSeries 630 Models 6C4 and 6E4 Service Guide
Summary of Contents for eserver 630 6C4
Page 1: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 00 ERserver IBM ...
Page 2: ......
Page 3: ...pSeries 630 Model 6C4 and Model 6E4 Service Guide SA38 0604 00 ERserver IBM ...
Page 16: ...xiv Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 18: ...xvi Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 52: ...System Logic Flow Diagram 32 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 64: ...Internal Signal Cable Routing Diagram 44 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 70: ...50 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 302: ...282 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 350: ...330 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 366: ...346 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 478: ...System Parts 458 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 480: ...System Parts continued 460 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 482: ...Model 6E4 Cover Set and Brackets 462 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 484: ...464 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 494: ...474 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 504: ...484 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 508: ...488 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 526: ...506 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 536: ...516 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 560: ...540 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 568: ...548 Eserver pSeries 630 Models 6C4 and 6E4 Service Guide ...
Page 571: ......
Page 572: ...IBM Printed in U S A August 2002 SA38 0604 00 ...