11.
Turn on the blade server, start the Configuration/Setup Utility program, and
reset the configuration (see “Setup and configuration overview” on page 19
for instructions).
Removing and replacing field replaceable units
Use this information to remove and replace field replaceable units (FRUs).
FRUs must be installed only by trained service technicians. The illustrations in this
document might differ slightly from your hardware.
Removing a microprocessor and heat sink
Use this information to remove a microprocessor and heat sink from the blade
server.
Read the following important guidelines before you remove a microprocessor that
is not faulty (for example, when you are replacing the system-board assembly).
If you are not replacing a defective heat sink or microprocessor, the thermal
material on the heat sink and microprocessor will remain effective if you carefully
handle the heat sink and microprocessor when you remove or install these
components. Do not touch the thermal material or otherwise allow it to become
contaminated.
Notes:
1.
The microprocessor and heat sink assembly is a field-replaceable unit (FRU)
and must be replaced by a trained service technician. To contact an IBM service
representative, see “Hardware service and support” on page 177.
2.
The heat-sink FRU is packaged with the thermal material applied to the
underside. This thermal material is not available as a separate FRU. You must
replace the heat sink when new thermal material is required, such as when a
defective microprocessor is replaced or if the thermal material is contaminated
or has come in contact with another object other than its paired microprocessor.
3.
A heat-sink FRU can be ordered separately if the thermal material becomes
contaminated.
To remove a microprocessor, complete the following steps.
60
BladeCenter HS12 Type 8014, 8028 or 1916: Problem Determination and Service Guide
Summary of Contents for BladeCenter HS12 Type 1916
Page 1: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 36: ...24 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 186: ...174 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 190: ...178 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 198: ...186 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 60Y1601 Printed in USA 1P P N 60Y1601...