Error code
Description
Action
00151300
MCA: Excessive Recoverable Error Detected
Proc
1.
(Trained service technician only) Reseat the
microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
2.
Replace the following components one at a time,
in the order shown, restarting the blade server
each time:
a.
(Trained service technician only)
Microprocessor - See “Removing a
microprocessor and heat sink” on page 60 and
“Installing a microprocessor and heat sink” on
page 62.
b.
(Trained service technician only)
System-board assembly - See “Removing the
system-board assembly” on page 65 and
“Installing the system-board assembly” on
page 66.
00151350
Processor Machine Check Data a Bank=
xx
APIC ID=
xx
CR4=
xxxx xxxx
Additional data for debugging. See error codes
00151100, 00151200, and 00151300 for action.
00151351
Processor Machine Check Data b Address=
xxxx xxxx xxxx xxxx
Time stamp=
xxxx xxxx
xxxx xxxx
Additional data for debugging. See error codes
00151100, 00151200, and 00151300 for action.
00151352
Processor Machine Check Data b Status=
xxxx xxxx xxxx xxxx
Additional data for debugging. See error codes
00151100, 00151200, and 00151300 for action. If bit 10
of Data b status is set, do not replace the
microprocessor.
Chapter 6. Diagnostics
109
Summary of Contents for BladeCenter HS12 Type 1916
Page 1: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 36: ...24 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 186: ...174 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 190: ...178 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 198: ...186 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 60Y1601 Printed in USA 1P P N 60Y1601...