v
Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v
See Chapter 4, “Parts listing, Types 8014, 8028 and 1916,” on page 25 to determine
which components are CRUs and which components are FRUs.
v
If an action step is preceded by “(Trained service technician only),” that step must be
performed only by a trained service technician.
Error message
Action
Microprocessor halted
1.
Remove the blade server from the
BladeCenter unit; then, reinstall it. See
“Removing the blade server from the
BladeCenter unit” on page 33 and
“Installing the blade server in a
BladeCenter unit” on page 34.
2.
Reseat the microprocessor - See
“Removing a microprocessor and heat
sink” on page 60 and “Installing a
microprocessor and heat sink” on page
62.
3.
Replace the following components one at
a time, in the order shown, restarting the
blade server each time:
a.
(Trained service technician only)
Microprocessor - See “Removing a
microprocessor and heat sink” on
page 60 and “Installing a
microprocessor and heat sink” on
page 62.
b.
(Trained service technician only)
System-board assembly - See
“Removing the system-board
assembly” on page 65 and “Installing
the system-board assembly” on page
66.
Microprocessor temperature warning
1.
Make sure that the blade server is
sufficiently cooled.
2.
Make sure that the front bezel on the
blade server is not blocked.
3.
(Trained service technician only) Replace
microprocessor - See “Removing a
microprocessor and heat sink” on page
60 and “Installing a microprocessor and
heat sink” on page 62.
Firmware (BIOS) backup ROM corruption,
System board failure
1.
Update the blade server firmware - Go to
http://www.ibm.com/systems/
support/.
2.
Replace the optional expansion unit - See
“Removing an optional expansion unit”
on page 37 and “Installing an optional
expansion unit” on page 38.
Chapter 6. Diagnostics
83
Summary of Contents for BladeCenter HS12 Type 1916
Page 1: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 36: ...24 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 186: ...174 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 190: ...178 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 198: ...186 BladeCenter HS12 Type 8014 8028 or 1916 Problem Determination and Service Guide...
Page 203: ......
Page 204: ...Part Number 60Y1601 Printed in USA 1P P N 60Y1601...