Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
28030xxx RTC errors
RTC Error Notes
1. Errors reported against the real
time clock (RTC) can be caused
by low battery voltage and (more
rarely) power outages that occur
during normal system usage.
These errors are warnings that the
RTC data content needs to be
re-established and do not require
any FRU replacement unless the
error is persistent. When one of
these errors occurs, the power-on
password and time and date
information has been lost.
v
To set/restore a power-on
password, use the SMS utility.
v
To set/restore the time and
date, use the operating system
facility.
2. If the error is persistent, replace
the battery on the system board.
Location: P1-V2
3. If the error is persistent after
battery replacement, replace the
system board.
Location: P1
(See note 3 on page 109.)
28030001 RTC initialization required. RTC not
updating, corrected.
1. Set the time and date.
2. Refer to error code 28030xxx on
page 124.
28030002 Bad time/date values
1. Set the time and date.
2. Refer to error code 28030xxx on
page 124.
28030003 RTC initalization required. RTC not
updating, corrected
Replace system board.
Location: P1
(See note 3 on page 109.)
28030004 Operating mode parameters changed (for
example data format).
1. Set the time and date.
2. Refer to error code 28030xxx on
page 124.
28030005 Battery error
1. Replace the battery.
Location: P1-V2
Note: Password, time and date
need to be set.
2. Refer to error code 28030xxx on
page 124 if the problem persists.
124
Service Guide
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...