Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
40200053 An inlet memory temperature condition
detected. (Critically high temperature
sensed at the air flow inlet.)
1. Check system unit fans.
Locations: F1, F2, F3, F4
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
40210011 A slow fan detected.
Check:
1. Room operating temperature.
2. Check system unit fans.
Locations: F1, F2, F3, F4
40210014 A stopped fan detected.
Replace the failing fan.
40A00000 The system firmware surveillance interval
was exceeded (System firmware
surveillance time-out).
1. Check for system firmware
updates
2. Go to the service processor main
menu and select System
Information Menu, then select
Read Progress Indicators from
Last System Boot. Begin your
repair action with the error code or
checkpoint immediately preceding
40A0 0000. If a location code
appears with the error code or
checkpoint, replace the part at that
location.
3. If the problem is not resolved, call
service support.
40B00000 The operating system surveillance
interval exceeded (operating system
surveillance time-out).
1. This error code indicates that the
operating system terminated early
(which usually implies an operating
system crash). This error code
may appear in the service
processor error log by itself.
However, in the AIX error log,
there should be another error
which points to the cause of the
operating system crash. Use the
other error as the starting point for
your service action.
2. Call service support.
40D00003 An unknown slow shutdown commanded.
Insure the ambient temperature is in
the proper range.
40D00004 An unknown fast shutdown occurred.
Insure the ambient temperature is in
the proper range.
40D00101 BIST on the system board failed.
Replace the system board. (See note
3 on page 109.)
40D00102 BIST on the system board failed.
Replace system board.
Location: P1
(See note 3 on page 109.)
Chapter 5. Error Code to FRU Index
151
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...