OS Surveillance Setup Menu
This menu can be used to set up operating system (OS) surveillance.
OS Surveillance Setup Menu
1. Surveillance:
Currently Enabled
2. Surveillance Time Interval:
5 Minutes
3. Surveillance Delay:
10 Minutes
98. Return to Previous Menu
– Surveillance
Can be set to enabled or disabled.
– Surveillance Time Interval
Can be set to any number from 1 to 255 minutes. The default value is 5 minutes.
– Surveillance Delay
Can be set to any number from 0 to 255 minutes. The default value of 10 minutes
is the recommended minimum.
Surveillance Time Interval and Surveillance Delay can only be changed after
surveillance is enabled. Refer to “Service Processor System Monitoring -
Surveillance” on page 204 for more information about surveillance.
v
Reset Service Processor
Allows the user to reinitialize the service processor.
v
Reprogram Service Processor Flash EPROM
Attention:
Only the service processor firmware can be updated from the service
processor menus; the system firmware cannot be updated from the service processor
menus. A service processor firmware update always requires a companion system
firmware update, which must be applied first. For this reason, updating only the
service processor firmware using the service processor menus is not recommended.
See the Web site at http://www.rs6000.ibm.com/support/micro to download the latest
firmware levels and update instructions.
The service processor firmware update image must be written onto a DOS-formatted
diskette. The update image can be obtained from the Web site at
http://www.rs6000.ibm.com/support/micro.
After the update diskette has been made, from the service processor main menu,
select Service Processor Setup. Then select Reprogram Service Processor Flash
EPROM. The program requests the update diskette(s) as they are needed. The
service processor will automatically reboot after the firmware update is complete.
Chapter 7. Using the Service Processor
185
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...