Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
25A80998 NVRAMRC script evaluation error -
command line execution error
Execution of a command line within
the NVRAM configuration variable
“NVRAMRC” (script) resulted in a
“throw” being executed. This script
can be modified by the system
firmware SMS utilities, the operating
system, PCI adapter ROM code or
utility, or an operator (through the
open firmware script editing command
nvedit). It may not be possible to
resolve the problem without a detailed
analysis of the NVRAM script, the
current system configuration, and
device tree contents.
1. The problem can be caused by a
SCSI controller/adapter, whose
SCSI bus ID has been changed
from the default setting, no longer
appearing in the system. This can
be caused either by removing a
SCSI controller/adapter, or a
problem with a SCSI
controller/adapter.
v
Select the SCSI ID utility from
the SMS menus.
a. Verify the list of SCSI
controllers/adapters. If the
list is not correct, suspect a
problem with the
controller/adapter that is
installed but not listed.
b. Select the option to save
the configuration
information.
c. Restart the system.
v
If the problem persists, boot the
operating system and verify the
SCSI bus IDs of any
installed/available SCSI
controllers/adapters (change as
necessary), and restart the
system.
2. Contact your service support
representative for further
assistance.
25A80999 NVRAMRC script evaluation error - stack
unbalanced on completion
This is a firmware debug environment
error. There is no user action or FRU
replacement.
Chapter 5. Error Code to FRU Index
119
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...