Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
25Cyy006 Memory DIMM failed inter-extent test.
1. Replace the memory card.
Location: P1-M1
2. Replace the processor card.
Location: P1-C1
Location: P1-C2
See Memory Error Notes on page 120
for more information.
25Cyy007 Memory DIMM failed extent access test.
1. Replace the memory card.
Location: P1-M1
2. Replace the processor card.
Location: P1-C1
Location: P1-C2
See Memory Error Notes on page 120
for more information.
25Cyy008 Memory DIMM has been deconfigured.
1. Use the memory config/deconfig
menu in the Service Processor
System Information Menu to check
the status of the memory DIMMs.
2. Go to “MAP 1240: Memory
Problem Resolution” on page 45.
26020001 Invalid PCI adapter vendor ID.
1. Move adapter to another slot
(behind another PCI bridge).
2. Check for available firmware
updates for adapter. Apply update
if available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter.
5. Check for system firmware
updates. Apply if update available.
6. Replace system board.
Location: P1
(See note 3 on page 109.)
Chapter 5. Error Code to FRU Index
121
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...