Step 1540-8
One of the FRUs remaining in the system unit is defective.
1. Turn off the power and remove the power cords.
2. Exchange the following FRUs in the order listed.
a. Memory card
b. System board (see notes on page 31)
c. Power supply
3. Plug in the power cords and wait for the OK on the operator panel display.
4. Turn on the power.
Does the system stop with code E1F2, E1F3, STBY or 4BA00830 displayed on the
operator panel?
NO
Reinstall the original FRU.
Repeat this step until the defective FRU is identified or all of the FRUs have
been exchanged.
If the symptom did not change and all the FRUs have been exchanged, call
service support for assistance.
If the symptom has changed, check for loose cards, cables, and obvious
problems, return to “Step 1540-1” on page 60 in this MAP, and follow the
instructions for the new symptom.
YES
Go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000
Eserver
pSeries
Diagnostic Information for Multiple Bus Systems.
Chapter 3. Maintenance Analysis Procedures (MAPs)
65
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...