Table 3. Firmware Error Codes. (continued)
Error Code Description
Action / Possible Failing FRU
28030006 Processor frequency measurement error
1. Verify that the current level of the
system firmware is installed.
2. Replace the processor card
Location: P1-C1
Location: P1-C2
3. Replace system board.
Location: P1
(See note 3 on page 109.)
Replacing the battery does not
correct this error condition.
28A00040 Power supply/fan errors
Check the following:
v
Ensure the I/O and media fans are
properly connected to the system
board.
v
Ensure the processor fan is
properly connected to the processor
card.
v
Reseat all suspected fans
connectors.
v
Look for obstructions that may
prevent the fans from normal
operations. (For example, a cable
caught in the fan, preventing it from
spinning.)
v
Replace any suspected fans that
may cause this error.
v
If after replacing the suspected
fans, the problem still exists:
– Replace the processor card for a
failing processor fan.
– Replace the system board
Location: P1
(See note 3 on page 109.)
28A00050 Power supply failure
1. Replace the power supply
specified by the location code.
2. Replace the power backplane.
Location: P3
29000002 Keyboard/mouse controller failed self-test. Replace the system board.
Location: P1
(See note 3 on page 109.)
29A00003 Keyboard not present/detected.
1. Keyboard
2. Replace the system board.
Location: P1
(See note 3 on page 109.)
Chapter 5. Error Code to FRU Index
125
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...