Step 1540-23
The adapter or device is probably defective.
If the supplemental medium is for an adapter, replace the FRUs in the following order:
1. Adapter
2. System board (see notes on page 31)
If the supplemental medium is for a device, replace the FRUs in the following order:
1. Device and any associated cables
2. The adapter to which the device is attached.
Repeat this step until the defective FRU is identified or all the FRUs have been
exchanged.
If the symptom did not change and all the FRUs have been exchanged, call service
support for assistance.
If the symptom has changed, check for loose cards, cables, and obvious problems. If
you do not find a problem, return to “Step 1540-1” on page 60 in this MAP and follow
the instructions for the new symptom.
Go to
″
MAP 0410: Repair Checkout
″
in the
RS/6000
Eserver
pSeries Diagnostic
Information for Multiple Bus Systems.
Step 1540-24
1. Ensure that the diagnostics and the operating system are shut down.
2. Turn off the power.
3. If you have not already done so, configure the service processor with the
instructions in note 6 on page 59 and then return here and continue.
4. Exit the service processor menus and remove the power cords.
5. Remove the service access cover (Model 6E1) or place the drawer (Model 6C1) into
the service position and remove the service access cover.
6. Record the slot numbers of the PCI adapters. Label and record the locations of any
cables attached to the adapters. Disconnect any cables attached to the adapters
and remove all the adapters.
7. Plug in the power cords and wait for OK on the operator panel display.
8. Turn on the power.
Does the system stop with the same error code displayed on the operator panel
that directed you to this MAP step?
NO
Go to “Step 1540-26” on page 78.
YES
Go to “Step 1540-25” on page 78.
Chapter 3. Maintenance Analysis Procedures (MAPs)
77
Summary of Contents for 265
Page 1: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 2: ......
Page 3: ...IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00 IBM...
Page 14: ...xii Service Guide...
Page 20: ...Fan Locations 1 2 3 4 1 Fan 1 2 Fan 2 3 Fan 3 4 Fan 4 4 Service Guide...
Page 46: ...30 Service Guide...
Page 96: ...80 Service Guide...
Page 190: ...174 Service Guide...
Page 287: ...Replacement Replace in reverse order Chapter 9 Removal and Replacement Procedures 271...
Page 308: ...292 Service Guide...
Page 324: ...308 Service Guide...
Page 328: ...312 Service Guide...
Page 354: ...338 Service Guide...
Page 363: ......
Page 364: ...IBM Printed in U S A February 2002 SA38 0609 00...
Page 365: ...Spine information IBM IntelliStation POWER 9112 Model 265 Service Guide SA38 0609 00...