manualshive.com logo in svg
background image

ASSEMBLY TEMPLATE

NOTE:

1.

MODEL VIEWS MAY NOT REPRESENT EXACT MODEL PURCHASED

PERIMETER WORKSTATION

2810K, 2810KF, 2820K, 2820KF, 2830K, 2830KF, 2840K, & 2840KF SERIES

ASSEMBLY INSTRUCTIONS

REVISION LEVEL

EMK

12/1/16

CREATED DRAWING

REV.

A

-

DWN

TITLE:

BY:

BY:

APR

DATE:

DWN

APR:

DATE

REVISION:

SCALE:

SHEET:

DRAWING NUMBER:

300 South Krueger Street

Suring, WI 54174

diversifiedwoodcrafts.com

THIS DRAWING IS THE SOLE PROPERTY OF
DIVERSIFIED WOOD CRAFTS. IT MAY NOT
BE ALTERED OR CHANGED WITHOUT
PERMISSION

BY:

APR

APR:

DATE

PERIMETER WORKSTATION

PERIMETER WORKSTATION
ASSEMBLY INSTRUCTIONS

REV A

1 OF 18

NTS

EMK

12/1/16

NAME

DATE

DESCRIPTION

ECN NO.

UNLESS OTHERWISE SPECIFIED

DIMENSION ARE IN INCHES

K:\DIVERSIFIED\ASSEMBLY INSTRUCTIONS\ACAD\2810K & KF, 2820K & KF, 2830K & KF,
2840K & KF SERIES.dwg, 11/29/2018 8:45:04 AM, DWG To PDF.pc3

Содержание 2810K Series

Страница 1: ...BER 300 South Krueger Street Suring WI 54174 diversifiedwoodcrafts com THIS DRAWING IS THE SOLE PROPERTY OF DIVERSIFIED WOOD CRAFTS IT MAY NOT BE ALTERED OR CHANGED WITHOUT PERMISSION BY APR APR DATE PERIMETER WORKSTATION PERIMETER WORKSTATION ASSEMBLY INSTRUCTIONS REV A 1 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES K DIVERSIFIED ASSEMBLY I...

Страница 2: ...ARIES TOP STYLE VARIES 1 00X18X90 BLK 1 TOP C VARIES TOP STYLE VARIES 1 00X4 00X90 BLK 1 CABINETS N A CABINET STYLE VARIES 24 W X 35 H X 16 D 4 REMOVABLE PANEL N A 0 75 THK X 42 W X 5 H 1 REMOVABLE PANEL N A 0 75 THK X 42 W X 30 H 1 REMOVABLE PANEL N A 0 75 THK X 24 25 W X 12 L 2 REMOVABLE PANEL N A 0 75 THK X 7 W X 35 H 2 SCREWS REMOVABLE PANELS 100495 SCREW 10X1 1 2 PHIL TR SMS ZN 30 APRON ASSEM...

Страница 3: ...ASSEMBLY COMPONENTS REV A 3 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES ASSEMBLY COMPONENTS ITEMS INCLUDED PART PART DESCRIPTION QTY ELECTRICAL BOX 100033 ELECTRICAL BOX 3 00X2X2 5 DEEP 2 ELECTRICAL OUTLET 100034 ELE OUT GFI 20A 125V BLK 2 FIXTURE FAUCETS 100074 BKR FIXTURE L65 WSA DIV MULTI SERVICE 2 FIXTURE SINK 100691 SINK EPOXY L3 BLK 1...

Страница 4: ...N PERIMETER WORKSTATION ASSEMBLY INSTRUCTIONS REV A 4 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES STEP 1 PLACE THE TWO CABINETS CLEATS ATTACHED TO THE SIDES AGAINST WALL CLEATS SHOULD BE FACING EACH OTHER LEAVE ENOUGH ROOM IN BETWEEN CABINETS FOR REMOVABLE PANELS LEVEL CABINETS ATTACH TO FLOOR B19 CABINET CLEATS ATTACHED TO RIGHT SIDE B18 C...

Страница 5: ...FIED DIMENSION ARE IN INCHES STEP 2 ATTACH LARGE REMOVABLE PANEL TO THE CLEATS ON THE CABINETS FIRST MAKE SURE BOTTOM EDGE OF PANEL IS FLUSH WITH BOTTOM EDGE OF CABINETS AND FRONT EDGE IS FLUSH WITH TOE KICK NOTCH ATTACH SMALL REMOVABLE PANEL ABOVE LARGE PANEL SECOND MAKE SURE PANEL IS FLUSH WITH TOP EDGES OF CABINETS PRE DRILL HOLES IN CLEATS TO PREVENT CRACKING SMALL REMOVABLE PANEL TOP EDGE SHO...

Страница 6: ...TER WORKSTATION ASSEMBLY INSTRUCTIONS REV A 6 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES STEP 3 PLACE THE OTHER TWO CABINETS WITH CLEATS ATTACHED TO BACK CENTERED IN FRONT OF CABINETS AGAINST WALL IN CORRECT LOCATION LEAVE ENOUGH ROOM IN BETWEEN CABINETS FOR REMOVABLE PANELS LEVEL CABINETS ANCHOR TO FLOOR 7 00 24 25 B18 CABINET CLEATS ATTA...

Страница 7: ...APR DATE PERIMETER WORKSTATION PERIMETER WORKSTATION ASSEMBLY INSTRUCTIONS REV A 7 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES STEP 4 ATTACH TWO SMALL REMOVABLE PANELS IN BETWEEN THE TWO BACK TO BACK CABINETS WITH HARDWARE PROVIDED PRE DRILL HOLES IN CLEATS TO PREVENT CRACKING REMOVABLE PANEL TYPICAL BACK TO BACK CABINETS TYPICAL WALL CABIN...

Страница 8: ...HE SIDE OF THE TWO BACK TO BACK CABINETS SO IT IS CENTERED CORRECTLY AND FLUSH WITH TOP OF BASE CABINETS PLACE THE L BRACKETS IN CORRECT POSITION ON APRON ASSEMBLY AND SIDE OF CABINETS SHOULD BE FLUSH WITH TOP EDGE OF CABINETS AND FRONT AND BACK OF APRONS MARK ON SIDE OF CABINETS WHERE L BRACKETS NEED TO BE ATTACHED SET APRON ASSEMBLY AND L BRACKETS DOWN CLOSE UP OF APRON ASSEMBLY AND SIDE ON BACK...

Страница 9: ...E ALTERED OR CHANGED WITHOUT PERMISSION BY APR APR DATE PERIMETER WORKSTATION PERIMETER WORKSTATION ASSEMBLY INSTRUCTIONS REV A 9 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES STEP 6 ATTACH L BRACKETS TO SIDE OF CABINETS WITH HARDWARE PROVIDED CLOSE UP OF SIDE ON BACK TO BACK CABINETS SHOWN L BRACKET TYPICAL K DIVERSIFIED ASSEMBLY INSTRUCTION...

Страница 10: ... 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES STEP 7 WITH HELP FROM ANOTHER PERSON PLACE APRON ASSEMBLY UP TO SIDE AND ATTACH TO L BRACKETS WITH HARDWARE PROVIDED SUPPORT THIS ASSEMBLY UNTIL TOP IS SECURED IT IS NOT STRONG ENOUGH TO WITHSTAND WEIGHT UNTIL TOP IS ATTACHED CLOSE UP OF APRON ASSEMBLY ATTACHED TO SIDE OF CABINETS SHOWN SIDE OF CABI...

Страница 11: ...SSEMBLY INSTRUCTIONS REV A 11 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES STEP 8 ATTACH REMAINING L BRACKETS TO THE TWO APRONS MAKE SURE BRACKETS ARE FLUSH WITH FRONT AND BACK EDGES OF APRONS AND TOP EDGE OF BRACKET IS FLUSH WITH TOP EDGE OF APRONS L BRACKETS TYPICAL ATTACHED TO APRONS FLUSH WITH FRONT AND BACK EDGES OF APRONS AND TOP EDGE ...

Страница 12: ...PERIMETER WORKSTATION ASSEMBLY INSTRUCTIONS REV A 12 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES STEP 9 ATTACH THE TWO APRONS IN BETWEEN THE BACK TO BACK CABINETS AND THE WALL CABINETS IN DESIRED LOCATION WITH REMAINING SCREWS PROVIDED CLOSE UP OF APRONS ATTACHED IN BETWEEN BACK TO BACK CABINETS AND WALL CABINETS SHOWN APRON TYPICAL WALL CA...

Страница 13: ... DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES STEP 10 PLACE TWO REMAINING REMOVABLE PANELS TO THE CLEATS ATTACHED ON LARGE REMOVABLE PANEL AND SIDES OF THE BACK TO BACK CABINETS NOT SHOWN ATTACH WITH REMAINING SCREWS PROVIDED THESE PANELS CAN BE REMOVED TO ACCESS PLUMBING AND GAS AT ANY TIME PRE DRILL HOLES IN CLEATS TO PREVENT CRACKING LARGE REMOVABLE PANEL BACK TO B...

Страница 14: ...EDGES OF CABINETS AND WINGS PLACE TOPS ON UNIT WITH PROPER OVERHANG CENTERED ON WORKSTATION APPLY A BEAD OF ADHESIVE TO EDGES OF THE TOPS WHERE THE TWO TOPS MEET AND PRESS FIRMLY TO CONNECT TOPS TOGETHER BE SURE TOP B IS TIGHT AGAINST WALL WIPE OFF ANY EXCESS CAULK CLAMP ON TOPS TO WINGS AND TOP RAILS OF CABINETS TO REMOVE ANY WARP USING SHIMS AND C CLAMPS IF NEEDED WHEN ALIGNING THE TOP DO THIS B...

Страница 15: ...LESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES TOP B TOP A APPLY SILICONE ADHESIVE AROUND OPENING FOR SINK TOP VIEW OF WORKSTATION SHOWN STEP 12 IF YOU DO NOT HAVE A K SERIES UNIT SKIP TO STEP 13 APPLY SILICONE ADHESIVE TO SINK OPENING ON TOP A LOWER SINK INTO OPENING APPLY SILICONE ADHESIVE TO CUT EDGE OF BACKSPLASH TOP C POSITION IT ON BACK EDGE OF TOP B ALONG THE WALL MAKE SURE BACKSPLASH IS ...

Страница 16: ...AY NOT BE ALTERED OR CHANGED WITHOUT PERMISSION BY APR APR DATE PERIMETER WORKSTATION PERIMETER WORKSTATION ASSEMBLY INSTRUCTIONS REV A 16 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES BACKSPLASH TOP C STEP 13 IF YOU HAVE ADJUSTABLE SHELVES IN YOUR UNIT INSERT SHELF CLIPS IN DESIRED LOCATION PLACE SHELVES ON CLIPS MAKING SURE THEY ARE LEVEL D...

Страница 17: ...WORKSTATION ASSEMBLY INSTRUCTIONS REV A 17 OF 18 NTS EMK 12 1 16 NAME DATE DESCRIPTION ECN NO UNLESS OTHERWISE SPECIFIED DIMENSION ARE IN INCHES COMPLETE UNIT SHOWN STEP 14 ATTACH RUBBER MOLDING TO BASE OF CABINETS USING CONTACT CEMENT SCREW STAINLESS STEEL CORNER BRACKETS ON EACH CORNER OVER BASE MOLDING WITH HARDWARE PROVIDED IF YOU HAVE A K SERIES UNIT INSTALL MULT SERVICE FIXTURES IN HOLES PRO...

Страница 18: ...ng in the same circuit If the RESET button doesn t pop out the GFCI is defective or malfunctioned and should be replaced If the GFCI is functioning properly and the lamp goes out press the RESET button to restore power to the outlet Conversely if you have a GFI that has tripped which is common and it will not reset you may have a wiring short in the circuit a defective appliance on the circuit or ...

Отзывы: