Relation between operation life and moment
The operation life depends on the moment acting on the slider.
With a light load, it may be longer than 10,000 km, the standard rated life.
With no consideration of vibration and mounting conditions, the operation life is 80,000 km
according to the calculation with the formula on the previous page, assuming that 0.5 C
M
(half of
dynamic allowable moment) of moment is applied.
We see that it can be 8 times longer than the standard rated life, which is 10,000 km.
10.2 Concept of life for controller
The controller part affecting service life is as follows.
Target part
Life
Condition
Electrolytic capacitor
5 years
Ambient temperature 40°C
Rated operation (operation within duty limits)
10.3 How to take concept of product life for motor drive DC power supply PSA-200
The consumable components in the motor drive DC power supply PSA-200 are as shown below.
Target part
Life
Condition
Electrolytic capacitor
5 years
Ambient temperature 55°C
Continuous rated output
Fan
3 years
Ambient temperature 55°C
Continuous rated output
Relay
100,000
times
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......