![IAI ELECYLINDER EC-S13 Instruction Manual Download Page 110](http://html1.mh-extra.com/html/iai/elecylinder-ec-s13/elecylinder-ec-s13_instruction-manual_604099110.webp)
3.4 Wiring connections (for connectors)
3.5 Wiring connections (for cables)
3-32
3. Wiring
Brake release wiring
For the specification with brake, when installing a forcible brake release switch, connect wiring
to the [B2] connector terminal.
Power capacity of 24V DC ±10% / 0.875 A (when in overexcitation), 0.085 A (when steady) is
required.
Pin
No.
Connector
nameplate
name
Signal
abbreviation
Compatible
wire diameter
Required specifications
B2
Brake
release
BKRLS
KIV 0.20 mm
2
(AWG24)
24 V DC ±10% /
0.875 A (when in overexcitation)
0.085 A (when steady)
3.5 Wiring connections (for cables)
Here the wiring connection method with a power I/O cable is introduced.
Power I/O cable
Note1 TMD2 is 24V (control)
(Note) Cable in light green and light gray not in use
ST0
ST1
RES
*ALM
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......