3.4 Wiring connections (for connectors)
3-22
3. Wiring
3.4 Wiring connections (for connectors)
(1) motor drive DC power supply PSA-200
Power supply connector
Follow the processes below to set up a connectivity of power supply cables for 100 V AC or
200 V AC.
1) Loosen the terminal screw with using such as a slotted screwdriver to open up the inlet.
2) Reveal the sheath for 7 mm on the cable
tip that satisfies the cable diameter complies the
specification shown in the table below and put it in the inlet.
3) Tighten the terminal screw with using such as a slotted screwdriver. The inlet closes and affixes
the wire.
4) Connect all the wires in the same manner and insert the enclosed connector to the power
supply connector.
Pin
No.
Connector
labeled name
Contents
Applicable cable diameter
1
L1
Motor AC power input
KIV 2.0 mm
2
(AWG14)
2
L2
3
L1C
Control AC power input
KIV 0.75 mm
2
(AWG18)
4
L2C
5
NC
Unconnected
6
PE
Protective ground line
KIV 2.0 mm
2
(AWG14)
1) Loosen the screw
with a slotted screwdriver
2) Insert wire
Wire inlet
3) Tighten the screw with
a slotted screwdriver
4) Plug in the enclosed connector to
the power connector on the
controller side
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......