3.5 Wiring connections (for cables)
3-36
3. Wiring
PLC wiring
For I/O between the PLC and signals, the wiring of the power I/O cable must be connected
to the PLC.
Connect the to wiring to the PLC terminal block while referring to the connection
diagram.
Connect the [orange] cable wire and the [Backward] output terminal.
Connect the [yellow] cable wire and the [Forward] output terminal.
Connect the [green] cable wire and the [Alarm clear] output terminal.
Connect the [blue] cable wire and the [Backward complete] input terminal.
Connect the [purple] cable wire and the [Forward complete] input terminal.
Connect the [gray] cable wire and the [Alarm] input terminal.
3
8
PLC connection
3
4
5
6
7
8
PLC
Process the terminals
in accordance with
PLC specifications
in order to conduct
wiring.
Enlarged view of power I/O cable
connector terminal section
ELECYLINDER / Power I/O cable
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......