![IAI ELECYLINDER EC-S13 Instruction Manual Download Page 103](http://html1.mh-extra.com/html/iai/elecylinder-ec-s13/elecylinder-ec-s13_instruction-manual_604099103.webp)
3.4 Wiring connections (for connectors)
3-25
3. Wiring
Regenerative resistor unit (Option)
Connect regenerative resistor unit (s) with attached cables as shown in the figure below.
1) When connecting 1 unit
: Connect RESU(D)-1 with the enclosed cable (CB-ST-REU)
2) When connecting 2 or more units : Connect RESU(D)-1 with the enclosed cable (CB-ST-REU)
● Wiring Image
● Specifications of external regenerative resistor connector
Item
Items and Model
Connector name
External regenerative resistor connector (RB)
Model
Controller side: GIC2.5/3-GF-7.62
Cable side: GIF2.5/3-STF-7.62
● Pin assignment
Pin No.
Signal
Name
Items
Applicable cable diameter
1
RB+
Regeneration r
(Motor drive DC voltage)
Dedicated cable is
enclosed to regenerative
resistor unit
2
RB-
Regeneration resistor-
3
PE
Ground terminal
RB IN
200 V power supply unit
External regenerative resistor
connector
1)
1)
RESU-1
RESUD-1
RESU-1
RESUD-1
RB OUT
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......