4.5 Operating method from master device
4-16
4. Operation
This shows the PLC timing chart for operating the ELECYLINDER.
The basic process is as follows.
[Basic timing chart]
Category
Signal
abbreviation
Timing chart
Remarks
1
Power
Power ON
24 V DC power supply is
turned ON.
Turn ON the motor drive DC
power supply PSA-200 next.
2
Output
* ALM
Turns ON if no alarm has
been triggered.
3
Input
ST1
Moves to the forward end.
4
Output
LS1
Moved to the forward end.
5
Input
ST0
Moves to the backward
end.
6
Output
LS0
Moved to the backward
end.
7
After this, "
3
" to "
6
" repeat.
Δ
t1: The time taken for the ELECYLINDER actually to reach the forward or backward end after the
LS signal turns ON. Consider
Δ
t1 when giving instructions for the next operation from the PLC
to the ELECYLINDER.
Δ
t1 becomes longer for larger detection ranges.
Δ
t1 also changes with the size of the transported load and acceleration/deceleration speeds.
Output
Input
ELECYLINDER →
output signals to PLC
PLC → input signals to
ELECYLINDER
Power ON
Move to forward end
Move to backward end
LED status: OFF →
Orange ON
→
Green ON
Δt1
Δt1
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......