3.5 Wiring connections (for cables)
3-37
3. Wiring
Brake release wiring
For the specification with brake, when installing a forcible brake release switch, connect the
[brown] cable wire.
Power capacity of 24 V DC ±10% / 0.875 A (when in overexcitation), 0.085 A (when steady) is
required.
Wiring
color
Signal
abbreviation
Function overview
Required specifications
Brown
BKRLS
Brake release
24 V DC ±10% /
0.875 A (when in overexcitation)
0.085 A (when steady)