3.3 Connection arrangement diagram
3-14
3. Wiring
3.3 Connection arrangement diagram
Motor drive DC power supply PSA-200
[1] Main power circuit
(Note) The power voltage of the controller (100 V AC or 200 V AC) cannot be changed.
Note: It is the model code when one unit of noise filter is connected to one unit of PSA-200.
Caution
For the noise filter, it is recommended to have one unit connected to one unit of
PSA-200.
Attach the surge protector if necessary considering the power supply condition.
It is recommended to attach it even though it is not mandatory.
Parts name
Model code
Supplier
Position to attach
Noise filter
NF2010A-UP (Note) SOSHIN ELECTRIC
CO., LTD
Attach in range of 300 mm
or less from controller
NAC-10-472
COSEL
Surge protector
R·A·V-781BWZ-2A
Okaya ELECTRIC
CO., LTD
Attach at the input
terminal of noise filter
L1 L2
L1
L1C
L2C
PE
L2
Circuit breaker
Noise filter
Surge protector
Earth leakage breaker
Power supply connector
Motor drive DC power supply
Motor power supply
Control power supply
Grounding resistance
at 100 Ω or less
(Grounding Class D)
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......