1.2 Mechanical specifications
1-13
1. Specifications
[Payload by Speed/Acceleration]
At low load capacity, the acceleration/deceleration can be increased.
The maximum acceleration/deceleration for Lead 30 and 20 is 1.0 G in the horizontal direction
and 0.7 G in the vertical direction.
The maximum acceleration/deceleration for Lead 10 is 0.7 G in the horizontal direction and
0.5 G in the vertical direction.
The maximum acceleration/deceleration for Lead 5 is 0.5 G in the horizontal direction and 0.3 G
in the vertical direction.
For % input, 1.0 G is set as 100%. 0.3 G should be set as 30%, and 0.5 G as 50%.
Lead 30
Maximum
speed
(mm/s)
Horizontal
Vertical
Acceleration (G)
0.3
0.5
0.7
1.0
0.3
0.5
0.7
1500
27.0
21.6
15.3
10.8
5.4
5.0
4.1
(Unit: kg)
Lead 20
Maximum
speed
(mm/s)
Horizontal
Vertical
Acceleration (G)
0.3
0.5
0.7
1.0
0.3
0.5
0.7
1000
40.5
31.5
20.7
13.5
9.0
7.7
6.3
(Unit: kg)
Lead 10
Maximum
speed
(mm/s)
Horizontal
Vertical
Acceleration (G)
0.3
0.5
0.7
1.0
0.3
0.5
0.7
500
81.0
59.4
36.0
-
18.0
15.3
-
(Unit: kg)
Lead 5
Maximum
speed
(mm/s)
Horizontal
Vertical
Acceleration (G)
0.3
0.5
0.7
1.0
0.3
0.5
0.7
250
90.0
72.0
-
-
30.6
-
-
(Unit: kg)
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......