3.4 Wiring connections (for connectors)
3-24
3. Wiring
[Connector guard]
As the cables equipped with a connector guard, a risk of them getting pulled out can be
prevented.
When pulling out the connector, insert a thin tool in a gap between the connector guard and
the connector to hold the locking feature, hold the other side at the same time and then pull it
out.
Also, by tightening the matching parts of the connector guards and the connectors with a tie-
band, concern of contact error at the connectors caused by vibration on the cables can be
reduced.
Connector guard
Lock
Lock
Push in a thin tool to a gap between the
connector guard and the locking feature
to hold the locking features on two sides
and then pull out the connector.
Tighten with tie-bands