6.4 Parameter function descriptions
6-10
6. Parameter
s
Parameter No.5: Smooth accel/decel setting
No. Category
Name
Symbol
Unit
Input range Default setting
at shipping
5
A
Smooth
accel/decel setting
MOD0
-
Disabled,
enabled
Disabled
● The movement waveform for ELECYLINDER operation can be selected.
● When [Enabled], accel/decel operation becomes smoother (less abrupt).
This softens the shocks of acceleration/deceleration without delaying the operation time.
● If [Disabled], the above functionality is not enabled.
Setting
Acceleration/deceleration
pattern
Operation waveform image
Disabled
Trapezoid
Enabled
S-motion
Caution
For operation in which the acceleration time or deceleration time exceeds 2 seconds,
do not [Enable] smooth accel/decel settings.
Normal operation will not be possible.
Avoid momentary stops during acceleration or deceleration operation.
Sudden changes (acceleration) will occur, which may be dangerous.
Time
Speed
Speed
Time
Summary of Contents for ELECYLINDER EC-S13
Page 2: ......
Page 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Page 10: ......
Page 66: ......
Page 116: ...3 38 3 Wiring ...
Page 136: ...4 18 4 Operation ...
Page 138: ......
Page 146: ......
Page 158: ...6 12 6 Parameters ...
Page 160: ......
Page 184: ...7 24 7 Troubleshooting ...
Page 186: ......
Page 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Page 232: ......
Page 238: ...9 6 9 External Dimensions ...
Page 240: ......
Page 244: ...10 4 10 Life ...
Page 246: ......
Page 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 250: ......
Page 256: ......
Page 257: ......