4. Operation
102 NEXIA-SY Series User Manual
2
Mold: W1
Pos2
Current Memory
Trvs
10.0
10.0
PFwBw
300.0
300.0
PAscDsc
0.0
0.0
1 Op
10%
Speed
-
DlyTime
- Sec
AscHeight
-
STEP 10
Press
DlyTime
- Sec
and input 0.3
Press
Speed
-
and input 80
Press
AscHeight
-
and input 100 mm.
2
Mold: W1
Pos2
Current Memory
Trvs
10.0
10.0
PFwBw
300.0
300.0
PAscDsc
0.0
0.0
1 Op
10%
Speed
80
DlyTime
0.8 Sec
AscHeight
100
STEP 11
Press
to move back to screen.
2
Mold: W1
Detail
Pitch
Times
FwBw
Trvs
MainPos
-
-
-
-
CLEAR
SubPos
Pos1
Pos4
Pos3
Pos2
STEP 12
Press
, move back to previous screen.