4. Operation
48 NEXIA-SY Series User Manual
(3) Example
1
Mold: COCK
MoldFile
NO Mold
1 COCK
1 COCK
STEP 1
Press
and move to new mold name set up
screen.
U V W X Y Z
.
K L
M N O P Q R S T
A B C D E F G H I
J
1
2 3 4 5 6 7 8 9 0
-
←
□
02
W1
No
Mold
1
Mold: COCK
NewMold
ENT
ENT
STEP 2
Press
to move cursor, Press
ENT
, save text.
Press
, move to origin (homing) screen
2
Mold: W1
SrchOrg
Search Org, Press “Start” Button.
10%
STEP 3
Press
, robot arm move to origing point of
new mold. Go back to main screen.