ET User’s Guide
3-13
Making Measurements
Using the BEGIN Key to Make Measurements
• Press
(Option 100 only) if you want to measure the
structural return loss of a cable. (The
selection is under the
menu.)
• Press
(Option 100 only) if you want to measure
the cable fault location. (The
selection is under
the
menu.)
Depending on your selection, the analyzer is set to one of the following
configurations. (The
and
configurations are
discussed in the Option 100 User's Guide Supplement.)
Table 3-1
Measurement Configurations from the BEGIN Key
The following measurement configurations apply to
all
of the measurement
types in the previous table:
Power Level
Factory preset power level
1
Measurement Channel 2
Off
Format
Log Mag
Number of Points
201
Sweep Time Mode
Auto
Sweep Triggering
Continuous
Averaging
Off
System Bandwidth
Medium Wide
1. Factory preset power level is user-defined by using the “Pwr Level at Preset” softkey. The fac-
tory default is 0 dBm.
SRL
SRL
Cable
Fault Location
Fault Location
Cable
SRL
Fault Location
Transmission
Reflection
Power
Conversion Loss
Frequency
Range
(HP 8712ET)
0.300 MHz to
1300 MHz
0.300 MHz to
1300 MHz
10 MHz to
1300 MHz
10 MHz to 1300 MHz
Frequency
Range
(HP 8714ET)
0.300 MHz to
3000 MHz
0.300 MHz to
3000 MHz
10 MHz to
3000 MHz
10 MHz to 3000 MHz
Measurement
Channel 1
Transmission
Reflection
Power
Conversion Loss
Detection
Mode
Narrowband
Narrowband
Broadband Internal Broadband Internal
Measurement
Paths
B/R
A/R
B*
B*/R*
Summary of Contents for HP 8712ET
Page 8: ...viii ET User s Guide ...
Page 17: ...ET User s Guide 1 1 1 Installing the Analyzer ...
Page 34: ...1 18 ET User s Guide Installing the Analyzer Preventive Maintenance ...
Page 35: ...ET User s Guide 2 1 2 Getting Started ...
Page 52: ...2 18 ET User s Guide Getting Started Performing the Operator s Check ...
Page 53: ...ET User s Guide 3 1 3 Making Measurements ...
Page 118: ...3 66 ET User s Guide Making Measurements Measuring Impedance Magnitude ...
Page 119: ...ET User s Guide 4 1 4 Using Instrument Functions ...
Page 143: ...ET User s Guide 4 25 Using Instrument Functions Using Markers Figure 4 15 Delta Marker Mode ...
Page 149: ...ET User s Guide 4 31 Using Instrument Functions Using Limit Testing Figure 4 16 Limit Lines ...
Page 207: ...ET User s Guide 5 1 5 Optimizing Measurements ...
Page 226: ...5 20 ET User s Guide Optimizing Measurements Measuring Devices with Long Electrical Delay ...
Page 227: ...ET User s Guide 6 1 6 Calibrating for Increased Measurement Accuracy ...
Page 266: ...6 40 ET User s Guide Calibrating for Increased Measurement Accuracy Checking the Calibration ...
Page 267: ...ET User s Guide 7 1 7 Front Rear Panel ...
Page 292: ...7 26 ET User s Guide Front Rear Panel Line Module ...
Page 293: ...ET User s Guide 8 1 8 Hardkey Softkey Reference ...
Page 395: ...ET User s Guide 9 1 9 Specifications ...
Page 397: ...ET User s Guide 9 3 Specifications System Performance ...
Page 443: ...ET User s Guide 10 1 10 Safety and Regulatory Information ...
Page 449: ...ET User s Guide 10 7 Safety and Regulatory Information Regulatory Information ...
Page 450: ...10 8 ET User s Guide Safety and Regulatory Information Regulatory Information ...
Page 451: ...ET User s Guide 11 1 11 Factory Preset State and Memory Allocation ...