ET User’s Guide
9-23
Specifications
Table 9-6
Test Port Input (continued)
a. The System Dynamic Range is calculated as the difference between the receiver noise floor
and the minimum of either the source maximum output (maximum power setting minus out-
put power level accuracy) or the receiver maximum input. System Dynamic Range applies to
transmission measurements only, since reflection measurements are limited by directivity.
The System Dynamic Range for HP 8714 ET/ES 75 W analyzers is not a specification for fre-
quencies >2 GHz; it is a characteristic. For the HP 8712ES/8714ES, external broadband detec-
tors will provide more dynamic range than the internal broadband detectors.
b. Option 1E1 adds a 60 dB step attenuator to the HP 8712ET/8714ET.
HP 8712ET/ES and HP 8714ET/ES Test Port Input
Description
Spec.
(in dB)
Typical
(in dB)
System Bandwidths:
Fine
(15 Hz)
Fine
(15 Hz)
Med Wide
(4000 Hz)
Wide
(6500 Hz)
System Dynamic Range
a
(continued)
HP 8714ET:
50
Ω
:
With Attenuator Option 1E1
b
:
Narrowband
112
120
95
57
Broadband (Internal)
57
64
57
41
Without Attenuator Option 1E1
Narrowband
114
121
96
58
Broadband (Internal)
59
65
58
42
75
Ω
:
With Attenuator Option 1E1
:
Narrowband
107
115
90
52
Broadband (Internal)
50
58
51
36
Without Attenuator Option 1E1
Narrowband
110
116
91
53
Broadband (Internal)
53
59
52
37
Summary of Contents for HP 8712ET
Page 8: ...viii ET User s Guide ...
Page 17: ...ET User s Guide 1 1 1 Installing the Analyzer ...
Page 34: ...1 18 ET User s Guide Installing the Analyzer Preventive Maintenance ...
Page 35: ...ET User s Guide 2 1 2 Getting Started ...
Page 52: ...2 18 ET User s Guide Getting Started Performing the Operator s Check ...
Page 53: ...ET User s Guide 3 1 3 Making Measurements ...
Page 118: ...3 66 ET User s Guide Making Measurements Measuring Impedance Magnitude ...
Page 119: ...ET User s Guide 4 1 4 Using Instrument Functions ...
Page 143: ...ET User s Guide 4 25 Using Instrument Functions Using Markers Figure 4 15 Delta Marker Mode ...
Page 149: ...ET User s Guide 4 31 Using Instrument Functions Using Limit Testing Figure 4 16 Limit Lines ...
Page 207: ...ET User s Guide 5 1 5 Optimizing Measurements ...
Page 226: ...5 20 ET User s Guide Optimizing Measurements Measuring Devices with Long Electrical Delay ...
Page 227: ...ET User s Guide 6 1 6 Calibrating for Increased Measurement Accuracy ...
Page 266: ...6 40 ET User s Guide Calibrating for Increased Measurement Accuracy Checking the Calibration ...
Page 267: ...ET User s Guide 7 1 7 Front Rear Panel ...
Page 292: ...7 26 ET User s Guide Front Rear Panel Line Module ...
Page 293: ...ET User s Guide 8 1 8 Hardkey Softkey Reference ...
Page 395: ...ET User s Guide 9 1 9 Specifications ...
Page 397: ...ET User s Guide 9 3 Specifications System Performance ...
Page 443: ...ET User s Guide 10 1 10 Safety and Regulatory Information ...
Page 449: ...ET User s Guide 10 7 Safety and Regulatory Information Regulatory Information ...
Page 450: ...10 8 ET User s Guide Safety and Regulatory Information Regulatory Information ...
Page 451: ...ET User s Guide 11 1 11 Factory Preset State and Memory Allocation ...