![Honda CBR125R Owner'S Manual Download Page 413](http://html1.mh-extra.com/html/honda/cbr125r/cbr125r_owners-manual_2157112413.webp)
LIGHTS/METERS/SWITCHES
19-21
FUEL LEVEL SENSOR
Remove the fuel pump unit (page 5-49).
Connect the ohmmeter to the fuel pump unit 5P
connector Yellow/white and Green terminals.
Inspect the resistance of the float at the full and
empty positions.
Replace the fuel pump unit assembly if fuel level
sensor is out of specification.
Install the fuel pump unit (page 5-50).
HORN
INSPECTION
Disconnect the connectors from the horn.
Connect a 12 V battery to the horn terminals.
The horn is normal if it sounds when the 12 V bat-
tery is connected across the horn terminals.
REMOVAL/INSTALLATION
Disconnect the wire connectors from the horn.
Remove the bolt and horn.
Install the horn in the reverse order of removal.
FUEL PUMP 5P CONNECTOR
(Wire side/female terminals)
G
Y/W
Float position:
FULL
EMPTY
Resistance:
6 – 10
Ω
90 – 100
Ω
FULL
EMPTY
FUEL PUMP 5P CONNECTOR
(Unit side/male terminals)
HORN
HORN
BOLT
WIRE CONNECTORS
Summary of Contents for CBR125R
Page 38: ...MEMO...
Page 56: ...MEMO...
Page 84: ...MEMO...
Page 94: ...FUEL SYSTEM PGM FI 5 2 FUEL SYSTEM PGM FI COMPONENT LOCATION 1 2 N m 0 1 kgf m 0 9 lbf ft...
Page 214: ...CYLINDER PISTON 9 2 CYLINDER PISTON COMPONENT LOCATION...
Page 224: ...MEMO...
Page 260: ...CRANKSHAFT BALANCER TRANSMISSION 12 2 CRANKSHAFT BALANCER TRANSMISSION COMPONENT LOCATION...
Page 282: ...MEMO...
Page 392: ...MEMO...
Page 416: ...MEMO...
Page 417: ...20 1 20 20 WIRING DIAGRAMS ED E F II G type 20 3 CM type 20 4 U type 20 5...
Page 428: ...MEMO...