Figure 5 - 16 simulates the correspondence between a given value and a set value
F5 - 29 AI curve 2 minimum input
0.00V
~
F5-31 [0.00V]
F5 - 30 AI curve 2 minimum input corresponding settings -100.0%
~
100.0% [0.0%]
F5 - 31 AI curve 2 maximum input
F5-29
~
10.00V [10.00V]
F5 - 32 AI curve 2 maximum input corresponding settings -100.0%
~
100.0% [100.0%]
F5 - 33 AI2 filtering time
0.00s
~
10.00s [0.10s]
For the function and usage of curve 2, please refer to the description of curve 1.
F5 - 34 AI curve 3 minimum input
0.00V
~
F5-36 [0.00V]
F5 - 35 AI curve 3 minimum input corresponding settings -100.0%
~
100.0% [0.0%]
F5 - 36 AI curve 3 maximum input
F5-34
~
10.00V [10.00V]
F5 - 37 AI curve 3 maximum input corresponding settings -100.0%
~
100.0% [100.0%]
F5 - 38 AI3 filtering time
0.00s
~
10.00s [0.10s]
For the function and usage of curve 3, please refer to the description of curve 1.
F5 - 39 AI curve selection
111
~
555 [321]
Bit: curve selection corresponding to AI1
1: Curve 1 (2 - point curve, see F5 - 24 ~ F5 - 27)
2: Curve 2 (2 - point curve, see F5 - 29 ~ F5 - 32)
3: Curve 3 (2 - point curve, see F5 - 34 ~ F5 - 37)
4: Curve 4 (4 - point curve, see F5 - 41 ~ F5 - 48)
5: Curve 5 (4 - point curve, see F5 - 49 ~ F5 - 56)
10 bits: the curve corresponding to AI2 are selected to be
1 - 5 and are the same as the individual bits.
100 bits: the curves corresponding to AI3 are selected to be
1 - 5 and are the same as the individual bits.
Notes:
The individual bit, ten bits and hundred bits of the function code are respectively used for selection, and analog
input AI1, AI2 and AI3 correspond to the set curves. 3 analog quantity input can select any one of the five curves.
Curve 1, curve 2, and curve 3 are all 2 - Point curve, while curve 4 and curve 5 are both 4 - point curves.
Correspondence setting
(Frequency / torque)
Correspondence setting