![HNC Electric HV480 Series User Manual Download Page 38](http://html.mh-extra.com/html/hnc-electric/hv480-series/hv480-series_user-manual_2142004038.webp)
34
Function
code
Name
Setting range
Factory
value
Communica
tion address
F5-35
AI curve 3 minimum input
corresponding settings
-100.0%
~
+100.0%
-100.0%
F523H
F5-36
AI curve 3 maximum
input
F5-34
~
+10.00V
10.00V
F524H
F5-37
AI curve 3 maximum
input corresponding
setting
-100.0%
~
+100.0%
100.0%
F525H
F5-38
AI3 filtering time
0.00s
~
10.00s
0.10s
F526H
F5-39
AI curve selection
Bits: AI1 curve selection
1: curve 1 ( 2 points, see F5 - 24 ~ F5 - 28 )
2: curve 2 ( 2 points, see F5 - 29 ~ F5 - 33 )
3: curve 3 ( 2 points, see F5 - 34 ~ F5 - 38 )
4: curve 4 ( 4 points, see F5 - 41 ~ F5 - 48 )
5: curve 5 ( 4 points, see F5 - 49 ~ F5 - 56 )
10 bits: AI2 curve selection, same as above
100 bits: AI3 curve selection, same as above
321
F527H
F5-40
AI is lower than the
minimum input setting
selection
Bits: AI1 lower than minimum input setting
selection
0: corresponding minimum input setting
1:0.0%
10 bits: AI2 is lower than the minimum input
setting selection, same as above
100 bits: AI3 is lower than the minimum input
setting selection, same as above
0
F528H
F5-41
AI curve 4 minimum input -10.00V
~
F5-43
0.00V
F529H
F5-42
AI curve 4 minimum input
corresponding settings
-100.0%
~
+100.0%
0.0%
F52AH
F5-43
AI curve 4 inflection point
1 input
F5-41
~
F5-45
3.00V
F52BH
F5-44
AI curve 4 inflection point
1 input corresponding
settings
-100.0%
~
+100.0%
30.0%
F52CH
F5-45
AI curve 4 inflection point
2 input
F5-43
~
F5-47
6.00V
F52DH
F5-46
AI curve 4 inflection point
2 input corresponding
settings
-100.0%
~
+100.0%
60.0%
F52EH
F5-47
AI curve 4 maximum
input
F5-45
~
+10.00V
10.00V
F52FH
F5-48
AI curve 4 maximum
input corresponding
setting
-100.0%
~
+100.0%
100.0%
F530H
F5-49
AI curve 5 minimum input -10.00V
~
F5-51
-10.00V
F531H
F5-50
AI curve 5 minimum input
corresponding settings
-100.0%
~
+100.0%
-100.0%
F532H
F5-51
AI curve 5 inflection point
1 input
F5-49
~
F5-53
-3.00V
F533H
F5-52
AI curve 5 inflection point
1 input corresponding
settings
-100.0%
~
+100.0%
-30.0%
F534H
F5-53
AI curve 5 inflection point
2 input
F5-51
~
F5-55
3.00V
F535H
F5-54
AI curve 5 inflection point
2 input corresponding
settings
-100.0%
~
+100.0%
30.0%
F536H