F5-54 AI curve 5 inflection point 2 input corresponding
settings
-100.0%
~
100.0%
【
60.0%
】
F5-55 AI curve 5 maximum input
F5-53
~
10.00V
【
10.00V
】
F5-56 AI curve 5 maximum input corresponding settings -100.0%
~
100.0%
【
100.0%
】
The functions of curve 4 and curve 5 are similar to those of curve 1 to curve 3, but curve 1 to curve 3 are 2 - point
straight lines, while curve 4 and curve 5 are 4 - point curves, which can realize more flexible correspondence. Figs. 5
- 17 are schematic diagrams of curves 4 to 5, taking curve 4 as an example.
Figure 5 - 17 schematic diagram of 4 - point curve
Notes:
When setting curve 4 and curve 5, you should pay attention to the following conditions: minimum input voltage of
curve < inflection point 1 voltage < Inflection point 2 voltage < maximum voltage
F5-65 AI1 sets jumping point
-100.0%
~
100.0%
【
0.0%
】
F5-66 AI1 sets jump amplitude
0.0% - 100.0%
【
0.5%
】
F5-67 AI2 sets jumping point
-100.0%
~
100.0%
【
0.0%
】
F5-68 AI2 sets jump amplitude
0.0% - 100.0%
【
0.5%
】
Analog input corresponding
set quantity (100 %)
Maximum input settings
corresponding to
Inflection point 1
corresponding setting F5-44
OV/0mA
Inflection point 2 corresponds
to setting F5 - 46
AI minimum input setting
F5 - 42
Inflection point 1 input
AI voltage input (10V)
Inflection point 2
input