Chapter IV Functional parameters
F0 - 46 is set to a value other than 0, i.e. the parameter protection password is set. In the function parameter mode
and the user change parameter mode, the parameter menu cannot be entered until the password is correctly entered.
To cancel the password, F0 - 46 needs to be set to 0.
Group F and group P are basic functional parameters, and group U is monitoring functional parameters.
4.1 Summary of basic functional parameters
Function
code
Name
Setting range
Factory
value
Communica
tion address
F0 group basic functions
F0-00
Menu mode selection
Bits: monitoring group U0
0: Not displayed
1: Display
Ten digits: special parameter group P
0: Not displayed
1: Display
11
F000H
F0-01
Control operation mode
0: No PG open loop vector control
1: PG closed loop vector control
2: V/F control
2
F001H
F0-02
Run command channel
selection
0: Operation panel
1: Terminals
2: Communication
0
F002H
F0-03
Main frequency source X
selection
0: Number setting 1
1: Number setting 2
2: AI1
3: AI2
4: AI3
5: X5 pulse given
6: Multi-segment instruction
7: Simple PLC
8: PID
9: Communication given
10: Potentiometer for keyboard given
1
F003H
F0-04
Anti - reverse selection
0: Allowed
1: Forbidden (0 frequency operation when
reverse command is applied)
0
F004H
F0-05
Phase sequence
selection
0: Standard
1: Carry out phase sequence exchange.
(rotation direction changes)
0
F005H
F0-06
Operation selection
when power is on
0: Allowed (when the power supply is turned on
and there is an operation command, the
operation will start.)
1: Prohibit (even if there is an operation
command while the power supply is on, the
motor selection is also prohibited.)
0
F006H
F0-07
JOG.K key function
selection
0: JOG.K is invalid
1: Operation panel command channel and
remote command channel ( terminal command
channel or communication command channel )
switch
2: Forward and reverse switching
3: Inching forward
4: Reverse inching
0
F007H