100
Pn No.
Size
Name
Setting range
Setting Unit
Factory
setting
Available
time
Categor
y
Rema
rks
Pn515
2 Output signal selection 5
0000
~
9999
-
0000
Power
restart
Setup
-
n.
X
Appointment parameters (do not change it)
n.
X
Distribution of command pulse input multiplication switching input (/PSEL)
Signal
0
CN1-IN0 takes effect when the input signal is ON.
1
CN1-IN1 takes effect when the input signal is ON.
2
CN1-IN2 takes effect when the input signal is ON.
3
CN1-IN3 takes effect when the input signal is ON.
4
CN1-IN4 takes effect when the input signal is ON.
5
CN1-IN5 takes effect when the input signal is ON.
6
CN1-IN6 takes effect when the input signal is ON.
7
CN1-IN7 takes effect when the input signal is ON.
8
Fixed the signal as "invalid" all the time.
9
Set the signal to "active" at all times.
n.
X
Appointment parameters (do not change it)
n.X
Appointment parameters (do not change it)
Pn516
2 Input signal selection 6
0000
~
9999
-
8888
Power
restart
Setup
-
n.
X
Distribution of forced stop input (FSTP) signal
Remarks
0
When the input signal of CN1-IN0 is ON (closed), drive can be
performed.
1
When the input signal of CN1-IN1 is ON (closed), drive can be
performed.
2
When the input signal of CN1-IN2 is ON (closed), drive can be
performed.
3
When the input signal of CN1-IN3 is ON (closed), drive can be
performed.
4
When the input signal of CN1-IN4 is ON (closed), drive can be
performed.
5
When the input signal of CN1-IN5 is ON (closed), drive can be
performed.
6
When the input signal of CN1-IN6 is ON (closed), drive can be
performed.
7
CN1-IN7 takes effect when the input signal is ON.
8
Fixed the signal as "invalid" all the time.
9
Set the signal to "active" at all times.
n.
X
Appointment parameters (do not change it)
n.X
Appointment parameters (do not change it)
Pn517
2 Input
signal
inversion
setting 0
0000
~
1111
-
0000
Power
restart
Setup
-
n.
X
CN1-IN0 terminal input signal inversion
0
Not reverse signal.
1
Reverses the signal.
n.
X
CN1-IN1 terminal input signal inversion
0
Not reverse signal.
1
Reverses the signal.
n.
X
CN1-IN2 terminal input signal inversion
0
Not reverse signal.
1
Reverses the signal.
n.X
CN1-IN3 terminal input signal inversion
0
Not reverse signal.
1
Reverses the signal.