S1 series standard inverter
-113-
Function
code
Name
Detailed parameter description
Default
value
Modify
oscillation control
factor of motor 2
You can modify this parameter to prevent current
oscillation.
Setting range of P04.23: 0
–100
Setting range of P04.24: 0
–100
Setting range of P04.25: 0.00 Hz
–P00.03 (Max.
output frequency)
P04.25
Oscillation control
threshold of
motor 2
30.00Hz
○
P04.26
Energy-saving
run
0: No action
1: Automatic energy-saving operation
Under light-load state, the motor can adjust the
output voltage automatically to achieve
energy-saving purpose
0
◎
P04.27
Channel of
voltage setup
0: Keypad; output voltage is determined by
P04.28
1: AI1
2: AI2
3: AI3
(
up to 2.2kW
)
4: HDI/HDIA
5: Multi-step (the set value is determined by P10
group)
6: PID
7: Modbus communication
8 - 13: Reserved
0
○
P04.28
Set voltage value
via keypad
When the channel for voltage setup is set to
"keypad", the value of this function code is digital
voltage set value.
Setting range: 0.0%
–100.0%
100.0%
○
P04.29
Voltage increase
time
Voltage increase time means the time needed
from outputting the min. voltage to accelerating to
output the max. voltage.
Voltage decrease time means the time needed
from outputting max. voltage to outputting the
min. voltage
Setting range: 0.0
–3600.0s
5.0s
○
P04.30
Voltage decrease
time
5.0s
○
P04.31
Output max.
voltage
Set the upper/lower limit value of output voltage.
100.0%
◎
P04.32
Output min.
voltage
0.0%
◎