S1 series standard inverter
-183-
the odd/even parity of the data is inconsistent with the preset information, it determines that a
communication error occurs.
CRC check mode
A frame in the RTU format includes an error detection domain based on the CRC calculation. The
CRC domain checks all the content of the frame. The CRC domain consists of two bytes, including 16
binary bits. It is calculated by the transmitter and added to the frame. The receiver calculates the CRC
of the received frame, and compares the result with the value in the received CRC domain. If the two
CRC values are not equal to each other, errors occur in the transmission.
During CRC, 0xFFFF is stored first, and then a process is invoked to process a minimum of 6
contiguous bytes in the frame based on the content in the current register. CRC is valid only for the
8-bit data in each character. It is invalid for the start, end, and check bits.
During the generation of the CRC values, the "exclusive or" (XOR) operation is performed on the
each 8-bit character and the content in the register. The result is placed in the bits from the least
significant bit (LSB) to the most significant bit (MSB), and 0 is placed in the MSB. Then, LSB is
detected. If LSB is 1, the XOR operation is performed on the current value in the register and the
preset value. If LSB is 0, no operation is performed. This process is repeated 8 times. After the last bit
(8
th
bit) is detected and processed, the XOR operation is performed on the next 8-bit byte and the
current content in the register. The final values in the register are the CRC values obtained after
operations are performed on all the bytes in the frame.
The calculation adopts the international standard CRC check rule. You can refer to the related
standard CRC algorithm to compile the CRC calculation program as required.
The following is a simple CRC calculation function for your reference (using the C programming
language):
unsigned int crc_cal_value(unsigned char×data_value,unsigned char data_length)
{
int i;
unsigned int crc_value=0xffff;
while(data_length--)
{
crc_value^=×dat+;
for(i=0;i<8;i++)
{
if(crc_value&0x0001)
crc_value=(crc_value>>1)^0xa001;
else
crc_value=crc_value>>1;
}
}
return(crc_value);
}
In the ladder logic, CKSM uses the table look-up method to calculate the CRC value according to the