S1 series standard inverter
-37-
Remarks: Press both the PRG/ESC and the DATA/ENT can return to the second-level menu from the
third-level menu. The difference is: pressing DATA/ENT will save the set parameters into the control
panel, and then return to the second-level menu with shifting to the next function code automatically;
while pressing PRG/ESC will directly return to the second-level menu without saving the parameters,
and keep staying at the current function code.
Under the third-level menu, if the parameter has no flickering bit, it means the function code cannot
be modified. The possible reasons could be:
1) This function code is not modifiable parameter, such as actual detected parameter, operation
records and so on;
2) This function code is not modifiable in running state, but modifiable in stop state.
Example: Set function code P00.01 = 1.
PRC
ESC
PRC
ESC
DATA
ENT
PRC
ESC
DATA
ENT
PRC
ESC
DATA
ENT
The ones place is blinking.
All digits are blinking.
The ones place is blinking.
The ones place is blinking.
Note:
When setting the value, you can press and + to modify the value.
»
SHIFT
Fig 5.4 Sketch map of modifying parameters
5.4.2 How to set the password of the inverter
S1 series inverters provide password protection function to users. Set P7.00 to gain the password
and the password protection becomes valid instantly after quitting from the function code editing state.
Press PRG/ESC again to the function code editing state,
“0.0.0.0.0” will be displayed. Unless using
the correct password, the operators cannot enter it.
Set P7.00 to 0 to cancel password protection function.
The password protection becomes effective instantly after retreating from the function code editing
state. Press PRG/ESC again to the function code editing state,
“0.0.0.0.0” will be displayed. Unless
using the correct password, the operators cannot enter it.
PRC
ESC
PRC
ESC
DATA
ENT
PRC
ESC
DATA
ENT
The ones place is blinking.
All digits are blinking.
The ones place is blinking.
The ones place is blinking.
Note:
When setting the value, you can press and + to modify the value.
»
SHIFT
PRC
ESC
PRC
ESC
The ones place is blinking. The ones place is blinking.
Fig 5.5 Sketch map of password setting