S1 series standard inverter
-146-
Function
code
Name
Detailed parameter description
Default
value
Modify
Speed
Actual detection
value
Set detection
value
Time t
t1
t2
t2=P11.15
t1<t2, so the inverter continues running
dEu
Running
Fault output
Setting range: 0.0
–10.0s
P12 group Parameters of motor 2
P12.01
Rated power of
asynchronous
motor 2
0.1
–3000.0kW
Depend
on
model
◎
P12.02
Rated frequency
of asynchronous
motor 2
0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
◎
P12.03
Rated speed of
asynchronous
motor 2
1
–36000rpm
Depend
on
model
◎
P12.04
Rated voltage of
asynchronous
motor 2
0
–1200V
Depend
on
model
◎
P12.05
Rated current of
asynchronous
motor 2
0.8
–6000.0A
Depend
on
model
◎
P12.06
Stator resistance
of asynchronous
motor 2
0.001
–65.535Ω
Depend
on
model
○
P12.07
Rotor resistance
of asynchronous
motor 2
0.001
–65.535Ω
Depend
on
model
○
P12.08
Leakage
inductance of
asynchronous
motor 2
0.1
–6553.5mH
Depend
on
model
○
P12.09
Mutual
inductance of
asynchronous
0.1
–6553.5mH
Depend