S1 series standard inverter
-55-
Related parameter list:
Function
code
Name
Detailed parameter description
Default
value
P00.01
Running command channel
0: Keypad
1: Terminal
2: Communication
1
P00.15
Motor parameter autotuning
0: No operation
1: Rotary autotuning; carry out
comprehensive motor parameter
autotuning; rotary autotuning is used in
cases where high control precision is
required;
2: Static autotuning 1 (comprehensive
autotuning); static autotuning 1 is used in
cases where the motor cannot be
disconnected from load;
3: Static autotuning 2 (partial
autotuning) ; when current motor is motor
1, only P02.06, P02.07 and P02.08 will
be autotuned; when current motor is
motor 2, only P12.06, P12.07 and P12.08
will be autotuned.
0
P02.01
Rated power of
asynchronous motor 1
0.1
–3000.0kW
Depend
on model
P02.02
Rated frequency of
asynchronous motor 1
0.01Hz
–P00.03 (Max. output frequency) 50.00Hz
P02.03
Rated speed of
asynchronous motor 1
1
–36000rpm
Depend
on model
P02.04
Rated voltage of
asynchronous motor 1
0
–1200V
Depend
on model
P02.05
Rated current of
asynchronous motor 1
0.8
–6000.0A
Depend
on model
P02.06
Stator resistance of
asynchronous motor 1
0.001
–65.535Ω
Depend
on model
P02.07
Rotor resistance of
asynchronous motor 1
0.001
–65.535Ω
Depend
on model
P02.08
Leakage inductance of
asynchronous motor 1
0.1
–6553.5mH
Depend
on model
P02.09
Mutual inductance of
asynchronous motor 1
0.1
–6553.5mH
Depend
on model