S1 series standard inverter
-118-
Function
code
Name
Detailed parameter description
Default
value
Modify
terminal Sin.
COM
K
SB2
SB1
FWD
REV
SIn
The direction control during running is shown
below.
Sln
REV
Previous
running
direction
Current
running
direction
ON
OFF→ON
Forward
Reverse
Reverse
Forward
ON
ON→OFF
Reverse
Forward
Forward
Reverse
ON→OF
F
ON
Decelerate to stop
OFF
Sln: 3-wire control/Sin, FWD: Forward running,
REV: Reverse running
3: 3-wire control 2; This mode defines Sin as
enabling terminal. The running command is
generated by FWD or REV, and they control the
running direction. During running, the terminal Sin
should be closed, and terminal FWD or REV
generates a rising edge signal to control the
running and direction of inverter; the inverter
should be stopped by disconnecting terminal Sin.