S1 series standard inverter
-86-
Function
code
Name
Detailed parameter description
Default
value
keypad
P09.02
PID feedback source
0: AI1
1: AI2
2: AI3
3: High-speed pulse HDIA
4: Modbus communication
5 - 10: Reserved
0
P09.03
PID output characteristics
0: PID output is positive characteristic
1: PID output is negative characteristic
0
P09.04
Proportional gain (Kp)
0.00
–100.00
1.80
P09.05
Integral time (Ti)
0.01
–10.00s
0.90s
P09.06
Derivative time (Td)
0.00
–10.00s
0.00s
P09.07
Sampling cycle (T)
0.000
–10.000s
0.100s
P09.08
Limit of PID control
deviation
0.0
–100.0%
0.0%
P09.09
Upper limit value of PID
output
P09.10
–100.0% (max. frequency or
voltage)
100.0%
P09.10
Lower limit value of PID
output
-100.0%
–P09.09 (max. frequency or
voltage)
0.0%
P09.11
Feedback offline detection
value
0.0
–100.0%
0.0%
P09.12
Feedback offline detection
time
0.0
–3600.0s
1.0s
P09.13
PID control selection
0x0000
–0x1111
Ones:
0: Continue integral control after the
frequency reaches upper/lower limit
1: Stop integral control after the
frequency reaches upper/lower limit
Tens:
0: The same with the main reference
direction
1: Contrary to the main reference
direction
Hundreds:
0: Limit as per the max. frequency
1: Limit as per A frequency
Thousands:
0x0001