S1 series standard inverter
-66-
Function
code
Name
Detailed parameter description
Default
value
receiving the stop command
LED thousands:
∧
/
∨
keys and analog
potentiometer integral function
0: The Integral function is valid
1: The Integral function is invalid
P08.43
Reserved variables
/
/
P08.44
UP/DOWN terminal control
0x000
–0x221
Ones: Frequency enabling selection
0: Setting through the UP/DOWN
terminal is valid
1: Setting through the UP/DOWN
terminal is invalid
Tens: Frequency control selection
0: Valid only when P00.06=0 or P00.07=0
1: Valid for all frequency modes
2: Invalid for multi-step speed when
multi-step speed takes priority
Hundreds: Action selection at stop
0: Valid
1: Valid during running, clear after stop
2: Valid during running, clear after
receiving stop command
0x000
P08.45
UP terminal frequency
incremental change rate
0.01
–50.00 Hz/s
0.50 Hz/s
P08.46
DOWN terminal frequency
decremental change rate
0.01
–50.00 Hz/s
0.50 Hz/s
P17.00
Set frequency
0.00Hz
–P00.03 (Max. output frequency)
0.00Hz
P17.02
Ramps reference frequency 0.00Hz
–P00.03 (Max. output frequency)
0.00Hz
P17.14
Digital adjustment value
0.00Hz
–P00.03
0.00Hz
5.5.8 Analog input
S1 series inverter carries two analog input terminals (For model
≥
4kW, they are AI1 and AI2.AI1 is
0
–10V/0–20mA (voltage input or current input can be set by P05.50); AI2 is -10–10V; For models up
to 2.2kW,they are AI2 and AI3. AI2 is 0
–10V/0–20mA(voltage input or current input can be set by
jumpers); AI3 is -10
–10V) and two high-speed pulse input terminals. Each input can be filtered
separately, and the corresponding reference curve can be set by adjusting the reference corresponds
to the max. value and min. value.